Re: [SIESTA-L] TBtrans and broadening matrix

2022-07-04 Por tôpico Aleksandar Tomovic

Hi,

thank you very much for provided material!

Kind regards,

Aleksandar Tomovic


-- 
SIESTA is supported by the Spanish Research Agency (AEI) and by the European 
H2020 MaX Centre of Excellence (http://www.max-centre.eu/)


[SIESTA-L] TBtrans and broadening matrix

2022-06-27 Por tôpico Aleksandar Tomovic

Dear all,

I'm interested in finding the coupling of my device with the L/R 
electrode.
In the paper "Improvements on non-equilibrium and transport Green 
function techniques: The next-generation transiesta" there is a sentence 
that says that tbtrans saves all scalar quantities ⟨Mj|Γ L|Mj′ ⟩. 
However, after reviewing TBtrans manual chapter related to projected 
transmission and sisl documentation on tbtprojncSileTBtrans, I was still 
unable to retrieve that information. I would appreciate any hints that 
you could provide.


Kind regards,

Aleksandar Tomovic


-- 
SIESTA is supported by the Spanish Research Agency (AEI) and by the European 
H2020 MaX Centre of Excellence (http://www.max-centre.eu/)


Re: [SIESTA-L] How to rotate translate or move molecule from one position to another?

2019-05-01 Por tôpico Aleksandar Tomovic

Dear El-Abed,

you can use Avogadro software (it is free) to rotate your molecule. The 
easiest way would be to select molecule, then use option add center of 
atoms,
a usually copy coordinates to Origin, move center of atoms to 0,0,0 then 
return it to Avogadro, this step is because Avogardo rotates around 
origin.


Kind regards,

Aleksandar
--
Aleksandar Tomovic
Institute of Physics Belgrade
Pregrevica 118, 11080 Belgrade, Serbia
http://www.ipb.ac.rs/


On 2019-04-30 10:31, El-abed Haidar wrote:

Good afternoon all,
 I am trying to use a new molecule below:

 and I would like sandwich it between the gold electrodes i have used
in before. Relaxing the whole structure together after long time did
not work. I have taken the alternative of relaxing the structure on
its own. Then sandwich it directly onto the gold electrodes.
 My Problem is the molecule does not belong to the plane where it is
suppose to be sandwiched:

 Both are in complete different positions. Does anyone know what one
can do in this case?
 Any advice would be appreciated.
 Thank you!
 EL-Abed

  El-abed Haidar | Doctor of Philosophy (Science)
 Condensed Matter Theory (CMT) Group
 | School of Physics
 THE UNIVERSITY OF SYDNEY  | NSW | 2006




[SIESTA-L] Graphene transmission dependence on unit cell size

2019-02-12 Por tôpico Aleksandar Tomovic
Dear all,

my question is related to graphene transmission calculation using
transiesta (currently I'm using siesta 4.1b4).

I tried to obtain transmission for graphene sheet using
geometry given in Figure 3a
(https://www.beilstein-journals.org/bjnano/articles/6/164)
using the same set parameters. However while i get the correct shape of the
curve, my
transmission value is n times higher, where n would be be number of zigzag
unit cells
contained in the given graphene sheet.
If I use single zigzag unit cell I am able to reproduce the correct result.

My question would be, is there a problem with my siesta installation or is
there
a parameter that I am missing the would give correct value of transmission.

If neither is the case, what is the implication of this when i want to
calculate transmission
of graphene gap with a molecule (when i need to use larger graphene sheet like
the one from Figure 3a).

Kind regards,

Aleksandar