Re: [Therion] Two inner walls gives an error

2021-04-17 Thread עמרי גסטר
You're right, I switched the two parameters in my head...
It's been a while since I worked with therion.
Thanks Martin.

On Sat, Apr 17, 2021 at 5:04 PM Martin Sluka via Therion 
wrote:

> Inner wall should have the parameter -outline in. It means „outline“ or
> bedrock is inside area bounded by line „wall“.
>
> Martin
>
> 17. 4. 2021 v 15:22, ⁨עמרי גסטר⁩ <⁨omri...@gmail.com⁩>:
>
> In the first image the inner wall is defined "out" and the yellow tick
> facing outward and this works fine.
>
>
> ___
> Therion mailing list
> Therion@speleo.sk
> https://mailman.speleo.sk/listinfo/therion
>


-- 
בברכה,
עמרי גסטר
052-6124995
___
Therion mailing list
Therion@speleo.sk
https://mailman.speleo.sk/listinfo/therion


Re: [Therion] Two inner walls gives an error

2021-04-17 Thread Martin Sluka via Therion
Inner wall should have the parameter -outline in. It means „outline“ or bedrock 
is inside area bounded by line „wall“. 

Martin

> 17. 4. 2021 v 15:22, ⁨עמרי גסטר⁩ <⁨omri...@gmail.com⁩>:
> 
> In the first image the inner wall is defined "out" and the yellow tick facing 
> outward and this works fine.
> 

___
Therion mailing list
Therion@speleo.sk
https://mailman.speleo.sk/listinfo/therion


[Therion] Two inner walls gives an error

2021-04-17 Thread עמרי גסטר
Hi everyone,

Therion gives me an error for a situation that seems to be ok, maybe I'm
missing something or I may have found a bug.
In the first image the inner wall is defined "out" and the yellow tick
facing outward and this works fine.
In the second image I added another inner wall which is also defined "out"
and with the yellow tick facing outward and I get the error "multiple scrap
outer outlines not supported yet".
As far as I understand there shouldn't be an error because both inner walls
are defined correctly.


[image: image.png][image: image.png]

-- 
Omri
___
Therion mailing list
Therion@speleo.sk
https://mailman.speleo.sk/listinfo/therion