Re: [time-nuts] HP 5342A (18 GHz) vs 5352B (40 GHz) frequency counters
I've got a few of the 5342s their weak point is the sampler. It can be fixed if you have a die bonder all of mine have the option 1 which is either a 10544 or 10811 depending on vintage The 535x series are nice counters I've got a couple. The bad thing is parts are even less available because all the magic happened on a hybrid circuit which is NLA from keysight and was around $1800 when it was. As to the comment on GPIB it's very popular still as it's a universal interface with a defined interface which is vendor independent and every piece of gear we've bought recently has included it as a standard option. Yes instruments are coming with Ethernet but that's mainly for remote front panel operation. It's useful when you can send a field tech with an instrument who's a local in country have them connect and then you can drive from the comfort of your office and transfer results for analysis But for data collection and production LabView and GPIB still rule the roost. Sent from my iPhone > On Nov 21, 2014, at 5:29 PM, paul swed wrote: > > David a free opinion and thats about what its worth. > The 5342 counter was a good counter but very old now. > I used to use the 5342s for satellite work and always wanted one for home. > But given its age circa 1980 I believe, maybe it works or not at all > frequencies. > I would simply go with the 5352b because at least there is some chance to > find parts if needed. > As I say not a great answer. > Regards > Paul > WB8TSL > > > On Fri, Nov 21, 2014 at 4:51 PM, Dr. David Kirkby (Kirkby Microwave Ltd) < > drkir...@kirkbymicrowave.co.uk> wrote: > >> I am looking for a microwave frequency counter and won an auction for an 18 >> GHz 5342A with the GPIB option today @ £200 (GBP). I have just paid for >> that. >> >> I also have the chance to get a 5352B 40 GHz counter for £500. That has >> GPIB as standard. >> >> In the short/medium term I don't see much use for a 40 GHz counter, but I >> am giving consideration to buying the 40 GHz and selling the 18 GHz one. >> >> I would be interested to know if anyone has any opinions on the relative >> merrits of the two counters. >> >> Neither of these counters have ovens, but stability is not a major issue >> given they take a 10 MHz input. That said, foes anyone know if these take >> fairly common 10811A ovens? There is a chance I would use it in places >> where it would not practical to feed in 10 MHz. >> >> Dave >> ___ >> time-nuts mailing list -- time-nuts@febo.com >> To unsubscribe, go to >> https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts >> and follow the instructions there. > ___ > time-nuts mailing list -- time-nuts@febo.com > To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.
Re: [time-nuts] HP 5342A (18 GHz) vs 5352B (40 GHz) frequency counters
The manual stated HP5342A have a option 001, it's a HP10544 OCXO with PC card connector(A24), but when I opened my HP5342A, there is very limited space, I doubt it's whether can contain a big 10544 OCXO in there. So I always use a external 10MHz to feed my counter. Hui Zhang At 2014-11-22 05:51:16, "Dr. David Kirkby (Kirkby Microwave Ltd)" wrote: >I am looking for a microwave frequency counter and won an auction for an 18 >GHz 5342A with the GPIB option today @ £200 (GBP). I have just paid for >that. > >I also have the chance to get a 5352B 40 GHz counter for £500. That has >GPIB as standard. > >In the short/medium term I don't see much use for a 40 GHz counter, but I >am giving consideration to buying the 40 GHz and selling the 18 GHz one. > >I would be interested to know if anyone has any opinions on the relative >merrits of the two counters. > >Neither of these counters have ovens, but stability is not a major issue >given they take a 10 MHz input. That said, foes anyone know if these take >fairly common 10811A ovens? There is a chance I would use it in places >where it would not practical to feed in 10 MHz. > >Dave >___ >time-nuts mailing list -- time-nuts@febo.com >To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts >and follow the instructions there. ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.
Re: [time-nuts] HP 5342A (18 GHz) vs 5352B (40 GHz) frequency counters
I have one of the source locking "EIP", which works up to 90GHz, but used only for 60,xx GHz only, they are sometimes relative inexpensive available on e-bay, see here: http://www.ebay.com/itm/EIP-578-MICROWAVE-FREQUENCY-COUNTER-10Hz-TO-90GHz-INCL-SENSOR-/111503803566?pt=LH_DefaultDomain_0&hash=item19f62504ae 73 Alex On 11/21/2014 2:29 PM, paul swed wrote: David a free opinion and thats about what its worth. The 5342 counter was a good counter but very old now. I used to use the 5342s for satellite work and always wanted one for home. But given its age circa 1980 I believe, maybe it works or not at all frequencies. I would simply go with the 5352b because at least there is some chance to find parts if needed. As I say not a great answer. Regards Paul WB8TSL On Fri, Nov 21, 2014 at 4:51 PM, Dr. David Kirkby (Kirkby Microwave Ltd) < drkir...@kirkbymicrowave.co.uk> wrote: I am looking for a microwave frequency counter and won an auction for an 18 GHz 5342A with the GPIB option today @ £200 (GBP). I have just paid for that. I also have the chance to get a 5352B 40 GHz counter for £500. That has GPIB as standard. In the short/medium term I don't see much use for a 40 GHz counter, but I am giving consideration to buying the 40 GHz and selling the 18 GHz one. I would be interested to know if anyone has any opinions on the relative merrits of the two counters. Neither of these counters have ovens, but stability is not a major issue given they take a 10 MHz input. That said, foes anyone know if these take fairly common 10811A ovens? There is a chance I would use it in places where it would not practical to feed in 10 MHz. Dave ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there. ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there. ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.
Re: [time-nuts] HP 5342A (18 GHz) vs 5352B (40 GHz) frequency counters
Dr. Kirby, The 5242A Option 001 (high stability) used a 10544 oscillator, which. IIRC, is electrically interchangeable with the 10811. The 5352B Option 010 (high stability) uses the 10811 oscillator. Cheers, Dave M Dr. David Kirkby (Kirkby Microwave Ltd) wrote: I am looking for a microwave frequency counter and won an auction for an 18 GHz 5342A with the GPIB option today @ £200 (GBP). I have just paid for that. I also have the chance to get a 5352B 40 GHz counter for £500. That has GPIB as standard. In the short/medium term I don't see much use for a 40 GHz counter, but I am giving consideration to buying the 40 GHz and selling the 18 GHz one. I would be interested to know if anyone has any opinions on the relative merrits of the two counters. Neither of these counters have ovens, but stability is not a major issue given they take a 10 MHz input. That said, foes anyone know if these take fairly common 10811A ovens? There is a chance I would use it in places where it would not practical to feed in 10 MHz. Dave ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.
Re: [time-nuts] HP 5342A (18 GHz) vs 5352B (40 GHz) frequency counters
David a free opinion and thats about what its worth. The 5342 counter was a good counter but very old now. I used to use the 5342s for satellite work and always wanted one for home. But given its age circa 1980 I believe, maybe it works or not at all frequencies. I would simply go with the 5352b because at least there is some chance to find parts if needed. As I say not a great answer. Regards Paul WB8TSL On Fri, Nov 21, 2014 at 4:51 PM, Dr. David Kirkby (Kirkby Microwave Ltd) < drkir...@kirkbymicrowave.co.uk> wrote: > I am looking for a microwave frequency counter and won an auction for an 18 > GHz 5342A with the GPIB option today @ £200 (GBP). I have just paid for > that. > > I also have the chance to get a 5352B 40 GHz counter for £500. That has > GPIB as standard. > > In the short/medium term I don't see much use for a 40 GHz counter, but I > am giving consideration to buying the 40 GHz and selling the 18 GHz one. > > I would be interested to know if anyone has any opinions on the relative > merrits of the two counters. > > Neither of these counters have ovens, but stability is not a major issue > given they take a 10 MHz input. That said, foes anyone know if these take > fairly common 10811A ovens? There is a chance I would use it in places > where it would not practical to feed in 10 MHz. > > Dave > ___ > time-nuts mailing list -- time-nuts@febo.com > To unsubscribe, go to > https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts > and follow the instructions there. > ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.
[time-nuts] HP 5342A (18 GHz) vs 5352B (40 GHz) frequency counters
I am looking for a microwave frequency counter and won an auction for an 18 GHz 5342A with the GPIB option today @ £200 (GBP). I have just paid for that. I also have the chance to get a 5352B 40 GHz counter for £500. That has GPIB as standard. In the short/medium term I don't see much use for a 40 GHz counter, but I am giving consideration to buying the 40 GHz and selling the 18 GHz one. I would be interested to know if anyone has any opinions on the relative merrits of the two counters. Neither of these counters have ovens, but stability is not a major issue given they take a 10 MHz input. That said, foes anyone know if these take fairly common 10811A ovens? There is a chance I would use it in places where it would not practical to feed in 10 MHz. Dave ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.