[time-nuts] Power numbers
I don't have a Thunderbolt, but I do have a Z3801A. It's running off a 48V 1.6A switcher. Idle (no Z3801A) 4W, 6VA Normal (after warmup) 20W, 33VA During warmup 35W, 51VA Measurements are at the wall, using a Kill-A-Watt. They are down around $20 now. -- These are my opinions, not necessarily my employer's. I hate spam. ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.
Re: [time-nuts] Power numbers
My thunderbolt power measurements: Voltage Current (Trimble spec) Actual (during warm-up) Actual (in operation) +12 V 750 mA 530 mA 160 mA +5 V 400 mA 260 mA 260 mA -12 V 10 mA 3 mA 3 mA /tvb ___ time-nuts mailing list -- time-nuts@febo.com To unsubscribe, go to https://www.febo.com/cgi-bin/mailman/listinfo/time-nuts and follow the instructions there.