Re: [U2] PE72 Unidata will not start
Daniel McGrath DMcGrath at rocketsoftware.com writes: Okay, first, don't worried about RFS not being licensed. That is additional functionality that doesn't come with the Personal Edition. Since you are getting Start SMM first, you probably have not started the UniData engine. With this, you don't want to actually start SMM by itself directly. All you need to do is run 'startud' to start the UniData engine and it should all be fine. Regards, Dan McGrath U2 Product Manager Rocket Software 4600 S. Ulster Street **Suite 1100 **Denver, CO 80237 * USA Tel: +1.720.475.8098 * Fax: +1.617.630.7392 Email: dmcgrath at rs.com Web: www.rocketsoftware.com/u2 -Original Message- From: u2-users-bounces at listserver.u2ug.org [mailto:u2-users-bounces at listserver.u2ug.org] On Behalf Of Tom Gray Sent: Monday, October 10, 2011 2:24 PM To: u2-users at listserver.u2ug.org Subject: [U2] PE72 Unidata will not start Installed unidata PE7.2.7, tryimg to start unidata, udt.exe, receive the following messages: RFS is not licensed. SB_FLAG is turned off. Start SMM first! I have looked at the License and it hasn't expired this is a recient download I tried starting the SMM from the command prompt ___ U2-Users mailing list U2-Users at listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users ___ U2-Users mailing list U2-Users at listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users I went to the Bin directory and ran startud it echoed back with It could not start Unidata Service. The following services are running: Uni RPC Service Uni Objectcall Unidata Telnet Service Unidata Terminal Service ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users
Re: [U2] PE72 Unidata will not start
Check your logs under @udtbin - especially smm.log and smm.errlog (also double check them in @udtbin\saved_logs). There may be some clues in there. With licensed versions you need to restart everything after applying the license (reboot recommended) - but I'm not sure how the PE version deals with that. Double check with confprod.exe (in @udtbin) to make sure the license is correct and authorized. hth Colin Alfke Calgary, Canada -Original Message- From: Tom Gray Daniel McGrath writes: Okay, first, don't worried about RFS not being licensed. That is additional functionality that doesn't come with the Personal Edition. Since you are getting Start SMM first, you probably have not started the UniData engine. With this, you don't want to actually start SMM by itself directly. All you need to do is run 'startud' to start the UniData engine and it should all be fine. Regards, Dan McGrath -Original Message- From: Tom Gray Installed unidata PE7.2.7, tryimg to start unidata, udt.exe, receive the following messages: RFS is not licensed. SB_FLAG is turned off. Start SMM first! I have looked at the License and it hasn't expired this is a recient download I tried starting the SMM from the command prompt I went to the Bin directory and ran startud it echoed back with It could not start Unidata Service. The following services are running: Uni RPC Service Uni Objectcall Unidata Telnet Service Unidata Terminal Service ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users
[U2] PE72 Unidata will not start
Installed unidata PE7.2.7, tryimg to start unidata, udt.exe, receive the following messages: RFS is not licensed. SB_FLAG is turned off. Start SMM first! I have looked at the License and it hasn't expired this is a recient download I tried starting the SMM from the command prompt ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users
Re: [U2] PE72 Unidata will not start
Okay, first, don't worried about RFS not being licensed. That is additional functionality that doesn't come with the Personal Edition. Since you are getting Start SMM first, you probably have not started the UniData engine. With this, you don't want to actually start SMM by itself directly. All you need to do is run 'startud' to start the UniData engine and it should all be fine. Regards, Dan McGrath U2 Product Manager Rocket Software 4600 S. Ulster Street **Suite 1100 **Denver, CO 80237 * USA Tel: +1.720.475.8098 * Fax: +1.617.630.7392 Email: dmcgr...@rs.com Web: www.rocketsoftware.com/u2 -Original Message- From: u2-users-boun...@listserver.u2ug.org [mailto:u2-users-boun...@listserver.u2ug.org] On Behalf Of Tom Gray Sent: Monday, October 10, 2011 2:24 PM To: u2-users@listserver.u2ug.org Subject: [U2] PE72 Unidata will not start Installed unidata PE7.2.7, tryimg to start unidata, udt.exe, receive the following messages: RFS is not licensed. SB_FLAG is turned off. Start SMM first! I have looked at the License and it hasn't expired this is a recient download I tried starting the SMM from the command prompt ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users
Re: [U2] PE72 Unidata will not start
Since you are on Windows, check the services to confirm that all three started. -Original Message- From: u2-users-boun...@listserver.u2ug.org [mailto:u2-users-boun...@listserver.u2ug.org] On Behalf Of Daniel McGrath Sent: Monday, October 10, 2011 1:37 PM To: U2 Users List Subject: Re: [U2] PE72 Unidata will not start Okay, first, don't worried about RFS not being licensed. That is additional functionality that doesn't come with the Personal Edition. Since you are getting Start SMM first, you probably have not started the UniData engine. With this, you don't want to actually start SMM by itself directly. All you need to do is run 'startud' to start the UniData engine and it should all be fine. Regards, Dan McGrath U2 Product Manager Rocket Software 4600 S. Ulster Street **Suite 1100 **Denver, CO 80237 * USA Tel: +1.720.475.8098 * Fax: +1.617.630.7392 Email: dmcgr...@rs.com Web: www.rocketsoftware.com/u2 -Original Message- From: u2-users-boun...@listserver.u2ug.org [mailto:u2-users-boun...@listserver.u2ug.org] On Behalf Of Tom Gray Sent: Monday, October 10, 2011 2:24 PM To: u2-users@listserver.u2ug.org Subject: [U2] PE72 Unidata will not start Installed unidata PE7.2.7, tryimg to start unidata, udt.exe, receive the following messages: RFS is not licensed. SB_FLAG is turned off. Start SMM first! I have looked at the License and it hasn't expired this is a recient download I tried starting the SMM from the command prompt ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users ___ U2-Users mailing list U2-Users@listserver.u2ug.org http://listserver.u2ug.org/mailman/listinfo/u2-users