I've also encountered this bug, first thinking it was a bug with the KDE
battery indicator applet. Upower is giving incorrect energy-full values
when this is happening. I've attached my 'upower -d' output from when
this is happening, you can see that the energy-full values are way to
high. Restarting the upower.service solves the problem.