Re: Issue with Checkpoint restore( Beam pipeline)

2017-11-30 Thread Jins George
Thanks Aljoscha.  I have not tried with 1.3. I will try and check the 
behavior.


Regarding setting UIDs to operators from Beam, do you know if thats 
something planned for a near future release ?


Thanks,
Jins George

On 11/30/2017 01:48 AM, Aljoscha Krettek wrote:

Hi,

I think you might be running into a problem that is hard to solve with 
Flink 1.2 and Beam. As you noticed, it's a problem that Beam doesn't 
assign UIDs to operators, which is a problem. Flink 1.3 and even more 
Flink 1.4 are a bit more lenient in accepting changes to the graph, so 
you might have better luck when trying it with that. Did you try using 
a newer Beam/Flink version? Flink 1.4 should be out next week and 
shortly after that I'll also update the Beam dependency.


Best,
Aljoscha

On 29. Nov 2017, at 23:52, Jins George > wrote:


Hi,

I am running a Beam Pipeline on Flink 1.2 and facing an issue in 
restoring a job from checkpoint. If I modify my beam pipeline to add 
a new operator and  try to restore from the externalized checkpoint, 
I get the error


/java.lang.IllegalStateException: Invalid Invalid number of operator 
states. Found :56. Expected: 58//
//at 
org.apache.flink.util.Preconditions.checkState(Preconditions.java:195)//
//at 
org.apache.flink.streaming.runtime.tasks.StreamTask.checkRestorePreconditions(StreamTask.java:680)//
//at 
org.apache.flink.streaming.runtime.tasks.StreamTask.initializeState(StreamTask.java:650)//
//at 
org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:257)//

//at org.apache.flink.runtime.taskmanager.Task.run(Task.java:655)//
//at java.lang.Thread.run(Thread.java:745)/

From the savepoint guide [1], new operator added should be 
initialized without any state.  Any idea why this error is reported.


Also note, I am not setting a ID to my operator ( because Flink 
runner in Beam does set the operator name user provided in pipeline 
creation)


[1] 
https://ci.apache.org/projects/flink/flink-docs-release-1.3/setup/savepoints.html



Thanks,
Jins George






Re: Issue with Checkpoint restore( Beam pipeline)

2017-11-30 Thread Aljoscha Krettek
Hi,

I think you might be running into a problem that is hard to solve with Flink 
1.2 and Beam. As you noticed, it's a problem that Beam doesn't assign UIDs to 
operators, which is a problem. Flink 1.3 and even more Flink 1.4 are a bit more 
lenient in accepting changes to the graph, so you might have better luck when 
trying it with that. Did you try using a newer Beam/Flink version? Flink 1.4 
should be out next week and shortly after that I'll also update the Beam 
dependency.

Best,
Aljoscha 

> On 29. Nov 2017, at 23:52, Jins George  wrote:
> 
> Hi,
> 
> I am running a Beam Pipeline on Flink 1.2 and facing an issue in restoring a 
> job from checkpoint. If I modify my beam pipeline to add a new operator and  
> try to restore from the externalized checkpoint, I get the error 
> 
> java.lang.IllegalStateException: Invalid Invalid number of operator states. 
> Found :56. Expected: 58
> at org.apache.flink.util.Preconditions.checkState(Preconditions.java:195)
> at 
> org.apache.flink.streaming.runtime.tasks.StreamTask.checkRestorePreconditions(StreamTask.java:680)
> at 
> org.apache.flink.streaming.runtime.tasks.StreamTask.initializeState(StreamTask.java:650)
> at 
> org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:257)
> at org.apache.flink.runtime.taskmanager.Task.run(Task.java:655)
> at java.lang.Thread.run(Thread.java:745)
> 
> From the savepoint guide [1], new operator added should be initialized 
> without any state.  Any idea why this error is reported.
> 
> Also note, I am not setting a ID to my operator ( because Flink runner in 
> Beam does set the operator name user provided in pipeline creation)
> 
> [1]  
> https://ci.apache.org/projects/flink/flink-docs-release-1.3/setup/savepoints.html
>  
> 
> 
> 
> Thanks,
> Jins George



Issue with Checkpoint restore( Beam pipeline)

2017-11-29 Thread Jins George

Hi,

I am running a Beam Pipeline on Flink 1.2 and facing an issue in 
restoring a job from checkpoint. If I modify my beam pipeline to add a 
new operator and  try to restore from the externalized checkpoint, I get 
the error


/java.lang.IllegalStateException: Invalid Invalid number of operator 
states. Found :56. Expected: 58//
//at 
org.apache.flink.util.Preconditions.checkState(Preconditions.java:195)//
//at 
org.apache.flink.streaming.runtime.tasks.StreamTask.checkRestorePreconditions(StreamTask.java:680)//
//at 
org.apache.flink.streaming.runtime.tasks.StreamTask.initializeState(StreamTask.java:650)//
//at 
org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:257)//

//at org.apache.flink.runtime.taskmanager.Task.run(Task.java:655)//
//at java.lang.Thread.run(Thread.java:745)/

From the savepoint guide [1], new operator added should be initialized 
without any state.  Any idea why this error is reported.


Also note, I am not setting a ID to my operator ( because Flink runner 
in Beam does set the operator name user provided in pipeline creation)


[1] 
https://ci.apache.org/projects/flink/flink-docs-release-1.3/setup/savepoints.html



Thanks,
Jins George