好的, 明白



在 2020-09-17 20:29:09,"Jark Wu" <imj...@gmail.com> 写道:
>>  sink.buffer-flush.max-rows = '0' 导致每接收一条数据就插入数据库
>
>这个应该是个 bug,我建了个 issue:https://issues.apache.org/jira/browse/FLINK-19280
>
>Best,
>Jark
>
>On Thu, 17 Sep 2020 at 18:15, chenxuying <cxydeve...@163.com> wrote:
>
>> 环境是flink1.11.2+idea
>> sql:
>> CREATE TABLE sourceTable (
>>     platform STRING
>>     ,game_id bigint
>> ) WITH (
>>     ...
>> );
>> CREATE TABLE sinktable (
>>     platform STRING
>>     ,game_id bigint
>> ) WITH (
>>     'connector' = 'jdbc',
>>     'url' = '',
>>     'table-name' = '',
>>     'driver' = 'com.mysql.jdbc.Driver',
>>     'username' = '',
>>     'password' = '',
>>     'sink.buffer-flush.max-rows' = '2',
>>     'sink.buffer-flush.interval' = '30s'
>> );
>> insert into sinktable select platform,game_id from sourceTable;
>>
>>
>> 官方文档[1]中 , 说到 sink.buffer-flush.max-rows和sink.buffer-flush.interval
>> 这两个属性可以设置成 '0' 来禁用他 , 不过我试了下是不行
>> 如果设置如下
>>    sink.buffer-flush.max-rows = '0'
>>    'sink.buffer-flush.interval' = '60s'
>> 导致每接收一条数据就插入数据库
>> 如果设置如下
>>    sink.buffer-flush.max-rows = '10'
>>    'sink.buffer-flush.interval' = '0'
>> 导致无法插入数据库
>>
>>
>> [1]:
>> https://ci.apache.org/projects/flink/flink-docs-release-1.11/dev/table/connectors/jdbc.html#connector-options
>>
>>