Re: [Veritas-bu] Drive cleaning

2009-08-17 Thread Holowinski, Scott
The other thing to look at is your labels, do they end in L1 - like an LTO1 
tape label. If they do and the drive is an LTO4 it won't use it.  At least I 
know this is the case on my Scalar i2000.

I had to get new cleaning labels as all mine ended in L1 and they wouldn't work 
in the LTO4 drive.  Not sure if the drive wouldn't use them or if the robot 
would fail to load, but new labels fixed my problem.

Scott Holowinski
Shared Backup Administrator
OneNeck IT Services

-Original Message-
From: smwoodcrafts [mailto:netbackup-fo...@backupcentral.com]
Sent: Friday, August 14, 2009 6:55 AM
To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU
Subject: [Veritas-bu] Drive cleaning



smwoodcrafts wrote:
> Thanks Scott,
>
> Drive HCART
> Tapes HCART
> Cleaning tapes HC_CLN
>
> Your right that would have been too easy.


They appear to be configured with the same type but we are still having the 
problem.

My cleaning tapes are TDK Ultrium Universal cleaning tapes. It says it's for 
LTO 1, 2, 3 and 4 drives. Has anyone had a problem with these?

+--
|This was sent by dseym...@ap.org via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--




Privileged/Confidential Information may be contained in this message or 
attachments hereto. Please advise immediately if you or your employer do not 
consent to Internet email for messages of this kind. Opinions, conclusions and 
other information in this message that do not relate to the official business 
of this company shall be understood as neither given nor endorsed by it.
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] CLI license info on windows?

2009-08-17 Thread A Darren Dunham
I've got a little tool that looks for expiring licenses via
get_license_key.  But that doesn't appear to exist on Windows.

How can I dump the license information from a Windows machine?

Thanks!
-- 
Darren
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

2009-08-17 Thread MickS

Thanks Simon  :D 

WEAVER, Simon \(extern... wrote:
> Mick
> Not long at all - Maybe 2 mins max per Server really.
> Simon 
> 
> -Original Message-
> From: veritas-bu-bounces < at > mailman.eng.auburn.edu
> [mailto:veritas-bu-bounces < at > mailman.eng.auburn.edu] On Behalf Of MickS
> Sent: Monday, August 17, 2009 3:01 AM
> To: VERITAS-BU < at > mailman.eng.auburn.edu
> Subject: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !
> 
> 
> Hi Simon
> I'm planning a similar upgrade and would appreciate any input you have
> on timings. In particular how long did nbpushdata  take ?
> 
> Cheers
> Mick
> 
> 
> WEAVER, Simon \(extern... wrote:
> 
> > All
> > Just wanted to share with you my experience of the in place upgrade 
> > for NBU 5.1 MP7 to 6.5.2 Original Plan: Upgrade Master only, then do
> > 
> SAN Media Servers at a later date.
> 
> > However, due to issues with one Media Server and the nbpushdata
> > 
> command having problems communicating with one Media Server (Even though
> NBCC worked like a charm!), an issue had arisen that required Symantec
> Help! 
> 
> > In the end, it was easier to do an inplace upgrade for everything (Did
> > 
> not make me popular but its done!) and so far its gone ok-ish! 
> 
> > Main problem was 1 Media Server was offline, refused to do restores or
> > 
> backups. Turned out it was only Active for disks. Problem tied down to a
> corrupt ltid and oprd processes. These got repaired by a manual
> replacement of the files. No idea why it happened, as the box in
> question installed and upgraded flawlessly! 
> 
> > One major problem I have seen is with my Win2k3 Active/Passive Mail
> > 
> Cluster. Now reading some notes, its clear something has changed in
> terms of how 6.5 handles Virtual Server Names, but if anyone can shed
> any light on this, it would be appreciated. 
> 
> > The 5.1 Topology used to show the NODE1 and NODE2 as physical SSO SAN
> > 
> MEDIA SERVERS. I used the command BPSTUADD to create a Virtual Storage
> Unit called MAIL. This used to appear in the topology of Activity
> Monitor. 
> 
> > Now, it appears, when I run the backup, the topology shows the Virtual
> > 
> Name MAIL as a Computer Icon. As if it is doing the backups over the
> LAN. Worse still, the throughput is showing speeds as if it is LAN Based
> Backups !! 
> 
> > Not sure why this has happened, but if anyone has a Mail System in a
> > 
> 2-node cluster and was on 5.1 and now moved to 6.5, I would be
> interested to hear how yours is working! 
> 
> > Thanks !  
> > Regards
> > Simon
> > 
> 
> 
> +--
> |This was sent by mick.scott < at > rheis.co.nz via Backup Central.
> |Forward SPAM to abuse < at > backupcentral.com.
> +--
> 
> 
> ___
> Veritas-bu maillist  -  Veritas-bu < at > mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
> 
> This email (including any attachments) may contain confidential
> and/or privileged information or information otherwise protected
> from disclosure. If you are not the intended recipient, please
> notify the sender immediately, do not copy this message or any
> attachments and do not use it for any purpose or disclose its
> content to any person, but delete this message and any attachments
> from your system. Astrium disclaims any and all liability if this
> email transmission was virus corrupted, altered or falsified.
> -o-
> Astrium Limited, Registered in England and Wales No. 2449259
> Registered Office:
> Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
> ___
> Veritas-bu maillist  -  Veritas-bu < at > mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


+--
|This was sent by mick.sc...@rheis.co.nz via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] Drive cleaning

2009-08-17 Thread Preston, Douglas
Error 98 means it couldn't find any available media for the job.  NBU tracks 
max cleanings and how many are left on a cleaning tape.  Make sure there are 
still cleanings on the cartridge.  Most cleaning cartridges can provide 50 
drive cleanings.  They should be in Volume pool None

On the I2k you can slide the robot column to the right.  It won't hurt it.  The 
best way though if you want to have the library handle the cleanings is to use 
the partitioning utility on the library and add some slots for cleaning tapes.
I personally like to have NBU handle the cleanings as I have a busy system and 
I have had drives get downed by NBU due the drive being unreachable while the 
library was cleaning the drives.  When NBU handles it then drives stay up. 

-Original Message-
From: veritas-bu-boun...@mailman.eng.auburn.edu 
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of smwoodcrafts
Sent: Monday, August 17, 2009 8:02 AM
To: VERITAS-BU@MAILMAN.ENG.AUBURN.EDU
Subject: [Veritas-bu] Drive cleaning


Now when cleaning needs to be done and the job starts, it picks the cleaning 
tape and then it fails with a 98 error. I tried to go back and do it manually, 
but here I have an ADIC i2000 and can't manually put a cleaning tape in as the 
robot column is in the way. When I try to load via the screen, the partition 
doesn't see any drives. I would pull my hair out, if I had any.

+--
|This was sent by dseym...@ap.org via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] Drive cleaning

2009-08-17 Thread smwoodcrafts

Now when cleaning needs to be done and the job starts, it picks the cleaning 
tape and then it fails with a 98 error. I tried to go back and do it manually, 
but here I have an ADIC i2000 and can't manually put a cleaning tape in as the 
robot column is in the way. When I try to load via the screen, the partition 
doesn't see any drives. I would pull my hair out, if I had any.

+--
|This was sent by dseym...@ap.org via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] Oracle Backup Notification

2009-08-17 Thread Dave Markham
I'd personally edit /usr/openv/netbackup/bin/backup_exit_notify and put 
a test section in for various policies or clients to send different emails.

If you need a hand let me know

D

Neeraj Puri wrote:
> Dear Admins,
>  
> I was looking for a solution to send an e-mail confirmation after the 
> Oracle backup is completed. The option of "client sends e-mail" send a 
> lot of e-mails as it sends mail for each single stream of backup job.
>  
> Can you help!
>  
> Regards,
> Neeraj
> 
>
> ___
> Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
> http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
>   

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

2009-08-17 Thread WEAVER, Simon (external)
This was one reason why I decided about upgrading ALL servers in one
hit.
I was just unsure how some of our older 5.x boxes would take to run.

Simon 

-Original Message-
From: smpt [mailto:sm...@peppas.gr] 
Sent: Monday, August 17, 2009 1:43 PM
To: WEAVER, Simon (external); VERITAS-BU@mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

Yes,
More or lees the time is 2 min per media server.
But when we did a step upgrade to a customer, (first the master, then
some media etc), with 90 san media servers and the command nbpushdata
-upgrade_5x_hosts took about 5 hours.

stefanos

-Original Message-
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of WEAVER,
Simon (external)
Sent: Monday, August 17, 2009 1:44 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

Mick
Not long at all - Maybe 2 mins max per Server really.
Simon 

-Original Message-
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of MickS
Sent: Monday, August 17, 2009 3:01 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !


Hi Simon
I'm planning a similar upgrade and would appreciate any input you have
on timings. In particular how long did nbpushdata  take ?

Cheers
Mick


WEAVER, Simon \(extern... wrote:
> All
> Just wanted to share with you my experience of the in place upgrade 
> for NBU 5.1 MP7 to 6.5.2 Original Plan: Upgrade Master only, then do
SAN Media Servers at a later date.
> However, due to issues with one Media Server and the nbpushdata
command having problems communicating with one Media Server (Even though
NBCC worked like a charm!), an issue had arisen that required Symantec
Help! 
> In the end, it was easier to do an inplace upgrade for everything (Did
not make me popular but its done!) and so far its gone ok-ish! 
> Main problem was 1 Media Server was offline, refused to do restores or
backups. Turned out it was only Active for disks. Problem tied down to a
corrupt ltid and oprd processes. These got repaired by a manual
replacement of the files. No idea why it happened, as the box in
question installed and upgraded flawlessly! 
> One major problem I have seen is with my Win2k3 Active/Passive Mail
Cluster. Now reading some notes, its clear something has changed in
terms of how 6.5 handles Virtual Server Names, but if anyone can shed
any light on this, it would be appreciated. 
> The 5.1 Topology used to show the NODE1 and NODE2 as physical SSO SAN
MEDIA SERVERS. I used the command BPSTUADD to create a Virtual Storage
Unit called MAIL. This used to appear in the topology of Activity
Monitor. 
> Now, it appears, when I run the backup, the topology shows the Virtual
Name MAIL as a Computer Icon. As if it is doing the backups over the
LAN. Worse still, the throughput is showing speeds as if it is LAN Based
Backups !! 
> Not sure why this has happened, but if anyone has a Mail System in a
2-node cluster and was on 5.1 and now moved to 6.5, I would be
interested to hear how yours is working! 
> Thanks !  
> Regards
> Simon


+--
|This was sent by mick.sc...@rheis.co.nz via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential and/or
privileged information or information otherwise protected from
disclosure. If you are not the intended recipient, please notify the
sender immediately, do not copy this message or any attachments and do
not use it for any purpose or disclose its content to any person, but
delete this message and any attachments from your system. Astrium
disclaims any and all liability if this email transmission was virus
corrupted, altered or falsified.
-o-
Astrium Limited, Registered in England and Wales No. 2449259 Registered
Office:
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu




This email (including any attachments) may contain confidential
and/or privileged information or information otherwise protected
from disclosure. If you are not the intended recipient, please
notify the sender immediately, do not copy this message or any
attachments and do not use it for any purpose or disclose its
content to any person, but delete this message and any attachments
from your system. Astrium disclaims any and all liability if this
email transmission was virus corrupted, altered or falsified.
-o-
Astrium 

[Veritas-bu] Oracle Backup Notification

2009-08-17 Thread Neeraj Puri
Dear Admins,

I was looking for a solution to send an e-mail confirmation after the Oracle
backup is completed. The option of "client sends e-mail" send a lot of
e-mails as it sends mail for each single stream of backup job.

Can you help!

Regards,
Neeraj
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

2009-08-17 Thread smpt
Yes, 
More or lees the time is 2 min per media server.
But when we did a step upgrade to a customer, (first the master, then some
media etc), with 90 san media servers and the command nbpushdata
-upgrade_5x_hosts took about 5 hours.

stefanos

-Original Message-
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of WEAVER,
Simon (external)
Sent: Monday, August 17, 2009 1:44 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: Re: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

Mick
Not long at all - Maybe 2 mins max per Server really.
Simon 

-Original Message-
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of MickS
Sent: Monday, August 17, 2009 3:01 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !


Hi Simon
I'm planning a similar upgrade and would appreciate any input you have
on timings. In particular how long did nbpushdata  take ?

Cheers
Mick


WEAVER, Simon \(extern... wrote:
> All
> Just wanted to share with you my experience of the in place upgrade 
> for NBU 5.1 MP7 to 6.5.2 Original Plan: Upgrade Master only, then do
SAN Media Servers at a later date.
> However, due to issues with one Media Server and the nbpushdata
command having problems communicating with one Media Server (Even though
NBCC worked like a charm!), an issue had arisen that required Symantec
Help! 
> In the end, it was easier to do an inplace upgrade for everything (Did
not make me popular but its done!) and so far its gone ok-ish! 
> Main problem was 1 Media Server was offline, refused to do restores or
backups. Turned out it was only Active for disks. Problem tied down to a
corrupt ltid and oprd processes. These got repaired by a manual
replacement of the files. No idea why it happened, as the box in
question installed and upgraded flawlessly! 
> One major problem I have seen is with my Win2k3 Active/Passive Mail
Cluster. Now reading some notes, its clear something has changed in
terms of how 6.5 handles Virtual Server Names, but if anyone can shed
any light on this, it would be appreciated. 
> The 5.1 Topology used to show the NODE1 and NODE2 as physical SSO SAN
MEDIA SERVERS. I used the command BPSTUADD to create a Virtual Storage
Unit called MAIL. This used to appear in the topology of Activity
Monitor. 
> Now, it appears, when I run the backup, the topology shows the Virtual
Name MAIL as a Computer Icon. As if it is doing the backups over the
LAN. Worse still, the throughput is showing speeds as if it is LAN Based
Backups !! 
> Not sure why this has happened, but if anyone has a Mail System in a
2-node cluster and was on 5.1 and now moved to 6.5, I would be
interested to hear how yours is working! 
> Thanks !  
> Regards
> Simon


+--
|This was sent by mick.sc...@rheis.co.nz via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential
and/or privileged information or information otherwise protected
from disclosure. If you are not the intended recipient, please
notify the sender immediately, do not copy this message or any
attachments and do not use it for any purpose or disclose its
content to any person, but delete this message and any attachments
from your system. Astrium disclaims any and all liability if this
email transmission was virus corrupted, altered or falsified.
-o-
Astrium Limited, Registered in England and Wales No. 2449259
Registered Office:
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu



___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !

2009-08-17 Thread WEAVER, Simon (external)
Mick
Not long at all - Maybe 2 mins max per Server really.
Simon 

-Original Message-
From: veritas-bu-boun...@mailman.eng.auburn.edu
[mailto:veritas-bu-boun...@mailman.eng.auburn.edu] On Behalf Of MickS
Sent: Monday, August 17, 2009 3:01 AM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] FINALLY DONE!!! 5.1 -> 6.5.2 Upgrade !


Hi Simon
I'm planning a similar upgrade and would appreciate any input you have
on timings. In particular how long did nbpushdata  take ?

Cheers
Mick


WEAVER, Simon \(extern... wrote:
> All
> Just wanted to share with you my experience of the in place upgrade 
> for NBU 5.1 MP7 to 6.5.2 Original Plan: Upgrade Master only, then do
SAN Media Servers at a later date.
> However, due to issues with one Media Server and the nbpushdata
command having problems communicating with one Media Server (Even though
NBCC worked like a charm!), an issue had arisen that required Symantec
Help! 
> In the end, it was easier to do an inplace upgrade for everything (Did
not make me popular but its done!) and so far its gone ok-ish! 
> Main problem was 1 Media Server was offline, refused to do restores or
backups. Turned out it was only Active for disks. Problem tied down to a
corrupt ltid and oprd processes. These got repaired by a manual
replacement of the files. No idea why it happened, as the box in
question installed and upgraded flawlessly! 
> One major problem I have seen is with my Win2k3 Active/Passive Mail
Cluster. Now reading some notes, its clear something has changed in
terms of how 6.5 handles Virtual Server Names, but if anyone can shed
any light on this, it would be appreciated. 
> The 5.1 Topology used to show the NODE1 and NODE2 as physical SSO SAN
MEDIA SERVERS. I used the command BPSTUADD to create a Virtual Storage
Unit called MAIL. This used to appear in the topology of Activity
Monitor. 
> Now, it appears, when I run the backup, the topology shows the Virtual
Name MAIL as a Computer Icon. As if it is doing the backups over the
LAN. Worse still, the throughput is showing speeds as if it is LAN Based
Backups !! 
> Not sure why this has happened, but if anyone has a Mail System in a
2-node cluster and was on 5.1 and now moved to 6.5, I would be
interested to hear how yours is working! 
> Thanks !  
> Regards
> Simon


+--
|This was sent by mick.sc...@rheis.co.nz via Backup Central.
|Forward SPAM to ab...@backupcentral.com.
+--


___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

This email (including any attachments) may contain confidential
and/or privileged information or information otherwise protected
from disclosure. If you are not the intended recipient, please
notify the sender immediately, do not copy this message or any
attachments and do not use it for any purpose or disclose its
content to any person, but delete this message and any attachments
from your system. Astrium disclaims any and all liability if this
email transmission was virus corrupted, altered or falsified.
-o-
Astrium Limited, Registered in England and Wales No. 2449259
Registered Office:
Gunnels Wood Road, Stevenage, Hertfordshire, SG1 2AS, England
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu