Re: [Veritas-bu] NetApp and Scaler i2000

2009-05-22 Thread Spearman, David
Bryan,

Way way cool. I did remember to lun map the i2000. We had also tried unplugging 
the fibre. However the key was the two storage commands you listed. Once I ran 
those the i2000 came to life for the Netapp.

By the by, when I was looking through the KB's at Ontap I found one that 
specified that the Control 0 entry should be put in position 255 on the i2000. 
That's where I put mine and it works but I don't know if it really makes any 
difference.

David Spearman
County of Henrico

From: Bryan Bahnmiller [mailto:bbahnmil...@dtcc.com]
Sent: Friday, May 22, 2009 10:00 AM
To: Spearman, David
Subject: Re: [Veritas-bu] NetApp and Scaler i2000


David,

   Did you do your device mapping on the Scalar? I've used I2K's in the past, 
and once you get the I/O blades zoned in on your fabric, you have to make sure 
the device mapping in the I/O blades allows access to the tape drives.

  Another thought, you are using the NetApp supplied HBA's for tape drives, 
right? They use different HBA's for disk and tape.

  Oh, another thing, you may have to reset your tape hba ports. So, if you have 
a tape drive attached to, say, port 1c (card 1, port c) you have to reset the 
card oftentimes before it will see the drive. You may also have to do this when 
you re-cycle NBU. To do this, do:
> storage disable adapter 1c
> storage enable adapter 1c

Then you should be able to see the drives using "sysconfig -t" on the netapp.

  Another gotcha is that if the Scalar I/O blade has 1 WWNN with separate 
WWPN's for the ports on the blade, the NetApp will only look at the WWNN. So if 
you have 2 drives down 1 port and another 2 drives down another port, the 
NetApp will think those are the same 2 drives - with failover paths...

   Bryan



"Spearman, David" 
Sent by: veritas-bu-boun...@mailman.eng.auburn.edu

05/22/2009 08:47 AM

To

"veritas-bu@mailman.eng.auburn.edu" 

cc

Subject

[Veritas-bu] NetApp and Scaler i2000







I am trying to get ndmp running to our NetApp. (everything is working on ndmp 
to Celera) I have fc zoned the Scaler library to the NetApp and the Scaler 
seems to be happy enough with zones and lun mapping. However the NetApp is not 
playing nice. I have been through the Ontap 7.3 tape backup guide but no matter 
what I do the NetApp refuses to recognize the library and tape units. Anyone 
know where that last button to be pushed lives? I can three way just fine with 
my 6.5.3 system.

David Spearman
County of Henrico, Va.
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu



DTCC DISCLAIMER: This email and any files transmitted with it are confidential 
and intended solely for the use of the individual or entity to whom they are 
addressed. If you have received this email in error, please notify us 
immediately and delete the email and any attachments from your system. The 
recipient should check this email and any attachments for the presence of 
viruses. The company accepts no liability for any damage caused by any virus 
transmitted by this email.
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] NetApp and Scaler i2000

2009-05-22 Thread Randy Doering
On the NetApp, do the tape drives show up with the "sysconfig" command?

If not, you may need to offline/online the specific FC Host Adapter. See the 
fcadmin command after "priv set advanced".

Randy

 




From: "Spearman, David" 
To: "veritas-bu@mailman.eng.auburn.edu" 
Sent: Friday, May 22, 2009 9:47:08 AM
Subject: [Veritas-bu] NetApp and Scaler i2000

I am trying to get ndmp running to our NetApp. (everything is working on ndmp 
to Celera) I have fc zoned the Scaler library to the NetApp and the Scaler 
seems to be happy enough with zones and lun mapping. However the NetApp is not 
playing nice. I have been through the Ontap 7.3 tape backup guide but no matter 
what I do the NetApp refuses to recognize the library and tape units. Anyone 
know where that last button to be pushed lives? I can three way just fine with 
my 6.5.3 system.

David Spearman
County of Henrico, Va.
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


[Veritas-bu] NetApp and Scaler i2000

2009-05-22 Thread Spearman, David
I am trying to get ndmp running to our NetApp. (everything is working on ndmp 
to Celera) I have fc zoned the Scaler library to the NetApp and the Scaler 
seems to be happy enough with zones and lun mapping. However the NetApp is not 
playing nice. I have been through the Ontap 7.3 tape backup guide but no matter 
what I do the NetApp refuses to recognize the library and tape units. Anyone 
know where that last button to be pushed lives? I can three way just fine with 
my 6.5.3 system.

David Spearman
County of Henrico, Va.
___