Re: [Veritas-bu] bpend_notify

2008-11-07 Thread judy_hinchcliffe
Thanks. I want it to run on the master.

-Original Message-
From: Donaldson, Mark [mailto:[EMAIL PROTECTED] 
Sent: Friday, November 07, 2008 5:09 PM
To: Judy Hinchcliffe; VERITAS-BU@mailman.eng.auburn.edu
Subject: RE: [Veritas-bu] bpend_notify

parent_start_notify & parent_end_notify.

Documentation says they run on the client but it lies.  It only runs on
the master server.

and backup_exit_notify still works on the master server.

Before 6.x, there was no equivalent to the parent starts & end scripts.
It was a constant search to find a battle-hardened method to find when a
whole group of related backups stopped.

-M 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Friday, November 07, 2008 4:04 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] bpend_notify


In the old days we had both bpend_notify 
And backup_exit_notify

I an on 6.5.2a (unix)
Goodies only has bpend_notify

But bpend_notify runs after every CHILD finishes 

I need to run after the PARENT finishes.

Anybody know the name of the file that will wait for the Parent to
finish?

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] bpend_notify

2008-11-07 Thread Donaldson, Mark
parent_start_notify & parent_end_notify.

Documentation says they run on the client but it lies.  It only runs on
the master server.

and backup_exit_notify still works on the master server.

Before 6.x, there was no equivalent to the parent starts & end scripts.
It was a constant search to find a battle-hardened method to find when a
whole group of related backups stopped.

-M 

-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] On Behalf Of
[EMAIL PROTECTED]
Sent: Friday, November 07, 2008 4:04 PM
To: VERITAS-BU@mailman.eng.auburn.edu
Subject: [Veritas-bu] bpend_notify


In the old days we had both bpend_notify 
And backup_exit_notify

I an on 6.5.2a (unix)
Goodies only has bpend_notify

But bpend_notify runs after every CHILD finishes 

I need to run after the PARENT finishes.

Anybody know the name of the file that will wait for the Parent to
finish?

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu

___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] bpend_notify by policy only

2006-07-14 Thread Dustin D'Amour
Title: Message








Thanks Paul and Brian.  

 



Dustin D'Amour

Coyote Solutions Group

505.742.0066

www.coyotesolutions.com

 

"Relax...it's just an update for
the patch to fix the nerf that nerfed the fix for the update of the patch that
broke the fix that was fixed."



 






___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


Re: [Veritas-bu] bpend_notify by policy only

2006-07-14 Thread Paul Keating
Title: Message



just 
rename the bpend_notify file to 
bpend_notify.policyname.weeklyschedname
 
 
-- 

  
  -Original Message-From: 
  [EMAIL PROTECTED] 
  [mailto:[EMAIL PROTECTED] On Behalf Of Dustin 
  D'AmourSent: July 14, 2006 11:24 AMTo: 
  Veritas-bu@mailman.eng.auburn.eduSubject: [Veritas-bu] bpend_notify 
  by policy only
  
  Is there a way to have a 
  bpend_notify just for the weekly schedule?  Current setup is that we have 
  Policies for all the clients with two different schedules a daily and a 
  weekly.  I want to use the bpend_notify on the weeklies to delete the 
  compressed daily files on the master server which are from devices that cannot 
  have NetBackup Client installed on them.
   
  NetBackup 6.0 MP3 running on SLES 
  9.3


La version française suit le texte anglais.



This email may contain privileged and/or confidential information, and the Bank 
of
Canada does not waive any related rights. Any distribution, use, or copying of 
this
email or the information it contains by other than the intended recipient is
unauthorized. If you received this email in error please delete it immediately 
from
your system and notify the sender promptly by email that you have done so. 



Le présent courriel peut contenir de l'information privilégiée ou 
confidentielle.
La Banque du Canada ne renonce pas aux droits qui s'y rapportent. Toute 
diffusion,
utilisation ou copie de ce courriel ou des renseignements qu'il contient par une
personne autre que le ou les destinataires désignés est interdite Si vous 
recevez
ce courriel par erreur, veuillez le supprimer immédiatement et envoyer sans 
délai à
l'expéditeur un message électronique pour l'aviser que vous avez éliminé de 
votre
ordinateur toute copie du courriel reçu.
___
Veritas-bu maillist  -  Veritas-bu@mailman.eng.auburn.edu
http://mailman.eng.auburn.edu/mailman/listinfo/veritas-bu


RE: [Veritas-bu] bpend_notify script

2005-11-08 Thread Patrick Whelan



Please read the disclaimer at the bottom of this e-mail.



Don't forget to adjust the BPSTART_TIMEOUT or BPEND_TIMEOUT 
as appropriate unless the backup takes less than 300 seconds. 
:)
 
Regards,
 

Patrick 
Whelan Enterprise Systems 
Support (NetBackup) LCHClearnet 
+44 020 7426 7624 
Those who give up essential liberties for temporary safety deserve neither liberty nor safety.
~Benjamin Franklin
 
… and by that time no one was left to speak 
up.
~Martin Niemöller

  -Original Message-From: 
  [EMAIL PROTECTED] 
  [mailto:[EMAIL PROTECTED]On Behalf Of Jim   PeppasSent: 08 November 2005 12:35To: 
  veritas-bu@mailman.eng.auburn.eduSubject: RE: [Veritas-bu] 
  bpend_notify script
  Hi,
   
  What I usually do is 
  create a dummy policy to backup the boot.ini on the 
  client.
  For THAT policy I 
  create a bpstart_notigy script that runs the command to stop the db, run the 
  backup using the bpbackup command  with the -w option (dont forget to 
  open a user schedule for the policy) 
  After the backup ends, 
  it starts the db again.
   
   
  Regards,
  JimP
  
  
  From: [EMAIL PROTECTED] 
  [mailto:[EMAIL PROTECTED] On Behalf Of Yusuf 
  GEDIKOGLUSent: Tuesday, November 08, 2005 10:44 AMTo: 
  veritas-bu@mailman.eng.auburn.eduSubject: [Veritas-bu] bpend_notify 
  script
  
  Hi;
  I want to learn is there a way to configure nb to send only one times run 
  bpend_notify script for a multiple stream backup job.
  We use bpend and bpstart notify scripts to stop start mssql server while 
  backup job running. It is working properly but in one of my server that have 
   500 Gb data and backup time nearly 20 hours. We set multiple streams for 
  decrease the backup time but this time we have a problem in the mssql. the 
  backup jobs have multiple streams and when a streams ended it runs bpend   notify script and this script started the mssql server. but the backup job is 
  running well so it cause the problems. 
  Is there a way to set bpend notify script to run only one time when the 
  multiple stream backup job ended.
  I am waiting your advices
  

**
This email is intended for the named recipient(s) only. Its contents
are  confidential and may only be retained by the named recipient(s)
and may only be copied or  disclosed  with the consent of 
LCH.Clearnet Limited.   If you are not an intended recipient please
delete this e-mail and notify [EMAIL PROTECTED]

The contents  of this  email are  subject to  contract in all cases, 
and LCH.Clearnet Limited makes no contractual commitment save where
confirmed by hard copy.  LCH.Clearnet Limited accepts no liability, 
including liability for negligence, in respect of any statement in 
this email.

LCH.Clearnet Limited, Registered Office: Aldgate House, 
33 Aldgate High Street, London EC3N 1EA.Recognised as a Clearing 
House under the Financial Services & Markets Act 2000. Reg in England No.25932 
Telephone: +44 20 7426 7000  Internet: http://www.lchclearnet.com
**




RE: [Veritas-bu] bpend_notify script

2005-11-08 Thread Jim Peppas



Hi,
 
What I usually do is 
create a dummy policy to backup the boot.ini on the 
client.
For THAT policy I 
create a bpstart_notigy script that runs the command to stop the db, run the 
backup using the bpbackup command  with the -w option (dont forget to open 
a user schedule for the policy) 
After the backup ends, it 
starts the db again.
 
 
Regards,
JimP


From: [EMAIL PROTECTED] 
[mailto:[EMAIL PROTECTED] On Behalf Of Yusuf 
GEDIKOGLUSent: Tuesday, November 08, 2005 10:44 AMTo: 
veritas-bu@mailman.eng.auburn.eduSubject: [Veritas-bu] bpend_notify 
script

Hi;
I want to learn is there a way to configure nb to send only one times run 
bpend_notify script for a multiple stream backup job.
We use bpend and bpstart notify scripts to stop start mssql server while 
backup job running. It is working properly but in one of my server that have 
 500 Gb data and backup time nearly 20 hours. We set multiple streams for 
decrease the backup time but this time we have a problem in the mssql. the 
backup jobs have multiple streams and when a streams ended it runs bpend notify 
script and this script started the mssql server. but the backup job is running 
well so it cause the problems. 
Is there a way to set bpend notify script to run only one time when the 
multiple stream backup job ended.
I am waiting your advices