Hello. In our configuration process, it is not clear where the policer speed 
limit is on the inbound flow rate or the output direction speed limit on the 
interface. If it is in the direction, it would like to configure how the speed 
limit of the output direction should be configured.
set int state GigabitEthernet1/0/0  up
set int state GigabitEthernet2/0/0  up
set int ip address  GigabitEthernet1/0/0 1.1.1.1/24
set int ip address  GigabitEthernet2/0/0 2.1.1.1/24
classify table table-index 0 mask l3 ip4 dst
configure policer name test cir 100 cb 50 rate kbps conform-action transmit
classify session policer-hit-next test table-index 0 match l3 ip4 dst 1.1.1.2
set policer classify interface GigabitEthernet2/0/0 ip4-table 0


-=-=-=-=-=-=-=-=-=-=-=-
Links: You receive all messages sent to this group.

View/Reply Online (#9626): https://lists.fd.io/g/vpp-dev/message/9626
Mute This Topic: https://lists.fd.io/mt/22294608/21656
Group Owner: vpp-dev+ow...@lists.fd.io
Unsubscribe: https://lists.fd.io/g/vpp-dev/unsub  [arch...@mail-archive.com]
-=-=-=-=-=-=-=-=-=-=-=-

Reply via email to