[Wien] w2web + lava queuing system

2010-07-04 Thread celhin
Dear all,

I fixed the problem.

Best,
C?line Hin.

celhin celhin at MIT.EDU a ??crit??:

 Dear wien2k users,

 I try to launch jobs on lava queuing system from w2web. In the 
 execution type, I
 have bsub=cat %f  w2web-job;bsub -n4  hp2.bsub. Below is the 
 hp2.bsub script.
 This does not work. Any idea what's wrong?

 In addition, where can I find the master-job-template qsub-job0_lapw? 
 I do not
 find it in $WIENROOT.

 Best,
 C?line Hin.


 Script:

 #!/bin/csh
 #BSUB -o job.out
 #BSUB -e job.err

 cd /home/celine/wienessaie/Wienessaie_mpi/Si9

 # copy the machines file in
 #cp $TMPDIR/machines.wien2k .machines

 set mpijob=1

 echo nodes for this job: $LSB_HOSTS

 set proclist=`echo $LSB_HOSTS`
 set nproc=$#proclist
 echo number of processors: $nproc

 echo '#'  .machines

 # example for an MPI parallel lapw0
 #echo -n 'optimize.job:'  .machines
 #set i=1
 #while ($i = $nproc )
 #echo -n $proclist[$i]  .machines
 #@ i = $i + 1
 #end
 #echo ' ' .machines

 #example for k-point and mpi parallel lapw1/2
 set i=1
 while ($i = $nproc )
 echo -n '1:' .machines
 @ i1 = $i + $mpijob
 @ i2 = $i1 - 1
 echo $proclist[$i-$i2] .machines
 set i=$i1
 end
 echo 'granularity:1' .machines
 echo 'extrafine:1' .machines

 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien





[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread Kakhaber Jandieri
Dear Wien2k users!


I am trying to minimize the GaP supercell with Nitrogen-Nitrogen interstitial 
pair using 
min -i 100 -s 10 -j 'run_lapw -p -I -i 40 -ec 0.001 -fc 1.0 -cc 0.001'
I constructed the supercell with 64 atoms and replaced one P atom  by the pair 
of interstitial N atoms.
After 16 cycles the program stopped with following message:


. . . . . . . . . . .

in cycle 16ETEST: .0996   CTEST: -.0009901

ec cc and fc_conv 1 1 1

 

   stop

Fallback to compatibility mode with old save_lapw

broyden files deleted, clm*, dmat*, vorb*, vresp*, eece*, scf and struct files 
saved under GaPNN_1

27.977u 0.412s 0:28.89 98.2%   0+0k 0+20648io 0pf+0w

0.844u 0.336s 0:01.66 70.4%0+0k 1272+16896io 8pf+0w

clmextrapol_lapw has generated a new GaPNN.clmsum

 

and calculations were renewed.
Further, after 12 cycles, the program stopped again with the message:

 . . . . . . . .
in cycle 12ETEST: .0406   CTEST: -.0009842

ec cc and fc_conv 1 1 1

 

   stop

 :WARNING: Step size reduced due to overlapping spheres -- check RMT

28.185u 0.408s 0:29.11 98.1%   0+0k 0+20648io 0pf+0w

0.872u 0.320s 0:01.53 77.7%0+0k 0+16896io 0pf+0w

clmextrapol_lapw has generated a new GaPNN.clmsum

 

and so on without ending.
Initially the RMTs for Ga and P atoms were RMT(Ga,P)=2.0  and  for N atom ? 
RMT(N)=1.3
In isolated nitrogen molecule the interatomic distance is approximately 1.295 
Angstrom. 
I guessed that the interatomic distance between the interstitial N atoms in GaP 
supercell would be larger then 1.295 A. 
So I reduced the RMT for N atom and took RMT(N)=1.0, aiming to prevent the 
overlapping of spheres for N-N pair. (2*RMT(N)=1.06 A  1.295 A). 
In spite of that, the result of ?mini? remains the same ? the interatomic 
distance between the interstitial N atoms becomes even smaller (!!!) then that 
in
isolated nitrogen molecule and I still have the problem with overlapping 
spheres. 



[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread Kakhaber Jandieri
In addition to my previous letter. 

I thought that may be the problem is in very large difference between the 
RMT(Ga,P)=2.0 and RMT (N)=1.0, but I cannot increase the RMT(N) because 
of overlapping spheres and, on the other hand, I cannot decrease the RMT(Ga,P) 
because of charge leakage. 


Could somebody advice the solution of this problem?

I will be extremely thankful for any suggestion.



[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread shamik chakrabarti
Dear Kakhaber Jandieri Sir,

First of all I am sorry because I am
not able to answer your question instead of I am humbelly asking you a
question. You have replaced one P atom by a pair of N atom.
I am interested to know that how do you able to replace one atom by two
atoms?

With regards,

On Sun, Jul 4, 2010 at 5:17 PM, Kakhaber Jandieri 
Kakhaber.Jandieri at physik.uni-marburg.de wrote:

 In addition to my previous letter.

 I thought that may be the problem is in very large difference between the
 RMT(Ga,P)=2.0 and RMT (N)=1.0, but I cannot increase the RMT(N) because
 of overlapping spheres and, on the other hand, I cannot decrease the
 RMT(Ga,P) because of charge leakage.


 Could somebody advice the solution of this problem?

 I will be extremely thankful for any suggestion.

 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien




-- 
Shamik Chakrabarti
Research Scholar
Dept. of Physics  Meteorology
Material Processing  Solid State Ionics Lab
IIT Kharagpur
Kharagpur 721302
INDIA
-- next part --
An HTML attachment was scrubbed...
URL: 
http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20100704/bed04396/attachment.htm


[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread swati chaudhury
Hello,
first of all I think you can't replace one atom by a pair of atoms.
Set 5% less RMT for all types of atoms instead of reduction of RMT of N only 
and run mini.
best wishes.
swati

--- On Sun, 4/7/10, Kakhaber Jandieri Kakhaber.Jandieri at 
physik.uni-marburg.de wrote:

 From: Kakhaber Jandieri Kakhaber.Jandieri at physik.uni-marburg.de
 Subject: [Wien] Interstitial N-N pair in GaP supercell
 To: wien at zeus.theochem.tuwien.ac.at
 Date: Sunday, 4 July, 2010, 5:17 PM
 In addition to my previous letter. 
 
 I thought that may be the problem is in very large
 difference between the RMT(Ga,P)=2.0 and RMT (N)=1.0, but I
 cannot increase the RMT(N) because 
 of overlapping spheres and, on the other hand, I cannot
 decrease the RMT(Ga,P) because of charge leakage. 
 
 
 Could somebody advice the solution of this problem?
 
 I will be extremely thankful for any suggestion.
 
 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
 


[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread Kakhaber Jandieri
Dear Swati,

Thank you for advice, but I still want to clarify some questions:

first of all I think you can't replace one atom by a pair of atoms.

My final goal is to obtain the relaxed atom positions in GaP supercell
where one of the P atoms is replaced by the interstitial pair of 
Nitrogen-Nitrogen atoms.
To say truth, I am not sure in correctness of my approach but I did the
following:
Step1 - Using the program supercell I generated 2x2x2 supercell for
GaP containing 64 atoms
Step2 -  I construct a new supercell with 64  inequivalent atoms using
the positions obtained in Step1
Step3 -  I split one P atom in 2 atoms
Step4 -  I changed the atoms obtained in Step3 from P to N
Step5 -  I ran x sgroup. It converted my p supercell with 65
inequivalent atoms into the 111_p-42m supercell with 16 inequivalent atoms
Step6 - I ran the program mini.

Could you advice me the correct way for constructing the supercell with
interstitial pair of  N-N atoms in  GaP matrix?


Set 5% less RMT for all types of atoms instead of reduction of RMT of N
only and run mini

In interstitial N-N pair the interatomic distance between N atoms might be 
significantly smaller then the distance between Ga and P atoms.

If instead of 2.0 I take 5% less RMT, then how cam I prevent the overlapping of 
spheres between the N atoms in the interstitial pair?


Beforehand thankfull,
Kakha 

 



swati chaudhury wrote:
 Hello,
 first of all I think you can't replace one atom by a pair of atoms.
 Set 5% less RMT for all types of atoms instead of reduction of RMT of N only 
 and run mini.
 best wishes.
 swati

 --- On Sun, 4/7/10, Kakhaber Jandieri Kakhaber.Jandieri at 
 physik.uni-marburg.de wrote:

   
 From: Kakhaber Jandieri Kakhaber.Jandieri at physik.uni-marburg.de
 Subject: [Wien] Interstitial N-N pair in GaP supercell
 To: wien at zeus.theochem.tuwien.ac.at
 Date: Sunday, 4 July, 2010, 5:17 PM
 In addition to my previous letter. 

 I thought that may be the problem is in very large
 difference between the RMT(Ga,P)=2.0 and RMT (N)=1.0, but I
 cannot increase the RMT(N) because 
 of overlapping spheres and, on the other hand, I cannot
 decrease the RMT(Ga,P) because of charge leakage. 


 Could somebody advice the solution of this problem?

 I will be extremely thankful for any suggestion.

 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien

 
 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien

   



[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread Kakhaber Jandieri
Dear Shamik,

You have replaced one P atom by a pair of N atom.
I am interested to know that how do you able to replace one atom by two
atoms?

I described in details the corresponding procedures in my reply to Swati 
Chaudhury.
I already mentioned in this reply that I am not sure in the correctness of 
these procedures, but just now I do not know the correct alternative.

Best wishes,
Kakha





shamik chakrabarti wrote:
 Dear Kakhaber Jandieri Sir,

 First of all I am sorry because I am
 not able to answer your question instead of I am humbelly asking you a
 question. You have replaced one P atom by a pair of N atom.
 I am interested to know that how do you able to replace one atom by two
 atoms?

 With regards,

 On Sun, Jul 4, 2010 at 5:17 PM, Kakhaber Jandieri 
 Kakhaber.Jandieri at physik.uni-marburg.de wrote:

   
 In addition to my previous letter.

 I thought that may be the problem is in very large difference between the
 RMT(Ga,P)=2.0 and RMT (N)=1.0, but I cannot increase the RMT(N) because
 of overlapping spheres and, on the other hand, I cannot decrease the
 RMT(Ga,P) because of charge leakage.


 Could somebody advice the solution of this problem?

 I will be extremely thankful for any suggestion.

 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien

 



   
 

 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
   



[Wien] Interstitial N-N pair in GaP supercell

2010-07-04 Thread E.A.Moore
If you want to study a pair of interstitial N atoms, you must add two N atoms, 
not replace P. Or if you are replacing P by two interstitial N atoms, you 
remove one P and add two N at new positions. 
Interstitial means the atoms are not on lattice sites. 
If the reduced cell has 16 inequivalent atoms, it sounds as  though you have 64 
not 65 atoms, so possibly you have just replaced P by N on four sites. 

Are you trying to add an interstitial N2 molecule? If not why do you need two N 
atoms?

Elaine A. Moore


From: Kakhaber Jandieri [kakhaber.jandi...@physik.uni-marburg.de]
Sent: 04 July 2010 15:04
To: A Mailing list for WIEN2k users
Subject: Re: [Wien] Interstitial N-N pair in GaP supercell

Dear Swati,

Thank you for advice, but I still want to clarify some questions:

first of all I think you can't replace one atom by a pair of atoms.

My final goal is to obtain the relaxed atom positions in GaP supercell
where one of the P atoms is replaced by the interstitial pair of
Nitrogen-Nitrogen atoms.
To say truth, I am not sure in correctness of my approach but I did the
following:
Step1 - Using the program supercell I generated 2x2x2 supercell for
GaP containing 64 atoms
Step2 -  I construct a new supercell with 64  inequivalent atoms using
the positions obtained in Step1
Step3 -  I split one P atom in 2 atoms
Step4 -  I changed the atoms obtained in Step3 from P to N
Step5 -  I ran x sgroup. It converted my p supercell with 65
inequivalent atoms into the 111_p-42m supercell with 16 inequivalent atoms
Step6 - I ran the program mini.

Could you advice me the correct way for constructing the supercell with
interstitial pair of  N-N atoms in  GaP matrix?


Set 5% less RMT for all types of atoms instead of reduction of RMT of N
only and run mini

In interstitial N-N pair the interatomic distance between N atoms might be 
significantly smaller then the distance between Ga and P atoms.

If instead of 2.0 I take 5% less RMT, then how cam I prevent the overlapping of 
spheres between the N atoms in the interstitial pair?


Beforehand thankfull,
Kakha





swati chaudhury wrote:
 Hello,
 first of all I think you can't replace one atom by a pair of atoms.
 Set 5% less RMT for all types of atoms instead of reduction of RMT of N only 
 and run mini.
 best wishes.
 swati

 --- On Sun, 4/7/10, Kakhaber Jandieri Kakhaber.Jandieri at 
 physik.uni-marburg.de wrote:


 From: Kakhaber Jandieri Kakhaber.Jandieri at physik.uni-marburg.de
 Subject: [Wien] Interstitial N-N pair in GaP supercell
 To: wien at zeus.theochem.tuwien.ac.at
 Date: Sunday, 4 July, 2010, 5:17 PM
 In addition to my previous letter.

 I thought that may be the problem is in very large
 difference between the RMT(Ga,P)=2.0 and RMT (N)=1.0, but I
 cannot increase the RMT(N) because
 of overlapping spheres and, on the other hand, I cannot
 decrease the RMT(Ga,P) because of charge leakage.


 Could somebody advice the solution of this problem?

 I will be extremely thankful for any suggestion.

 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien


 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien



___
Wien mailing list
Wien at zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien

-- 
The Open University is incorporated by Royal Charter (RC 000391), an exempt 
charity in England  Wales and a charity registered in Scotland (SC 038302).