Hello,
As I recall, it is nonessential to change the value in case.inst. But the
change of NE in case.in2 is important.
It is straight to do so — when you change Fe 26 to 26.2 in case.struct, add
0.2*number of Fe (in the considered unit cell) to the existing NE.
The reason is simple --- With 26 to 26.2, the valence electron count is
increased.
Cheers,
Jianxin
#
Jian-Xin Zhu, Ph.D
Theoretical Division, MS B262
Los Alamos National Laboratory
Los Alamos, New Mexico 87545
Phone: (505) 667 2363 (T-4);
(505) 667 6602 (CINT)
Fax: (505) 665 4063
Email (main): jx...@lanl.gov
Email (backup): physjx...@gmail.com
#
From: Meng, Qingping qm...@bnl.govmailto:qm...@bnl.gov
Reply-To: A Mailing list for WIEN2k users
wien@zeus.theochem.tuwien.ac.atmailto:wien@zeus.theochem.tuwien.ac.at
Date: Thursday, January 15, 2015 3:21 PM
To: wien@zeus.theochem.tuwien.ac.atmailto:wien@zeus.theochem.tuwien.ac.at
wien@zeus.theochem.tuwien.ac.atmailto:wien@zeus.theochem.tuwien.ac.at
Subject: [Wien] virtual crystal approximation
Dear all,
I want to do virtual crystal calculation. I change Fe’s Z to 26.2. I also
change case.inst to:
Fe
Ar 3
3, 2, 2.0 N
3, 2, 2.0 N
3, -3, 2.5 N
3, -3, 0.0 N
4, -1, 1.0 N
4, -1, 0.7 N
I checked the Mail Archive. Someone said I also need change NE in case.in2. I
do not know how to change it, and why I need change NE. I also do not know NE’s
means. Could you tell me. Thank you.
Best,
Qingping Meng
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at: