[Wien] -eece and -hf switch for hybrid functionals

2012-08-13 Thread Peter Blaha
No. Where do you read this 

-eece  is exact exchange correlated electrons, and is a local version of HF 
for one type
of localized electrons (3d or f4). It is similar to LDA+U and very 
cheap.
-hfis full Hartree-Fock, applicable to all kind of systems. But it is very 
expensive
(and expensive does not mean it is better than plain GGA in many 
cases). If you
don't know why you want to use it, don't use it.

Am 12.08.2012 23:20, schrieb ali ghafari:
 Dear Prof. Blaha
 Thank you very much for replay.
 As I understand from UG (page 68 ) in the last step of Self-consistent 
 calculation for full hybrids
 we should use -hf and -eece together i.e run(sp)_ lapw -hf -eece ...
   Is it right?
 Best Regards
 Ali

 
 *From:* Peter Blaha pblaha at theochem.tuwien.ac.at
 *To:* A Mailing list for WIEN2k users wien at zeus.theochem.tuwien.ac.at
 *Sent:* Sunday, August 12, 2012 7:26 PM
 *Subject:* Re: [Wien] -eece and -hf switch for hybrid functionals

 No, full hybrids are not supported in w2web. You have to use the command line 
 and
 follow the procedures indicated in the UG.

 Am 12.08.2012 15:52, schrieb ali ghafari:
   Dear Prof. Blaha and users
  
   In the page 68 of UG, it has mentioned that for using hybrid functionals 
 such as B3LYP we should use
   -hf switch while at the w2web only -eece is possible. Could you please 
 tell me when we select -eece switch
   it automatically add -hf switch? or we should only use -hf at the terminal?
  
   Best Regards
   Ali
  
  
   ___
   Wien mailing list
   Wien at zeus.theochem.tuwien.ac.at mailto:Wien at 
 zeus.theochem.tuwien.ac.at
   http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
  

 --
 -
 Peter Blaha
 Inst. Materials Chemistry, TU Vienna
 Getreidemarkt 9, A-1060 Vienna, Austria
 Tel: +43-1-5880115671
 Fax: +43-1-5880115698
 email: pblaha at theochem.tuwien.ac.at mailto:pblaha at 
 theochem.tuwien.ac.at
 -
 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at mailto:Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien




 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien


-- 
-
Peter Blaha
Inst. Materials Chemistry, TU Vienna
Getreidemarkt 9, A-1060 Vienna, Austria
Tel: +43-1-5880115671
Fax: +43-1-5880115698
email: pblaha at theochem.tuwien.ac.at
-


[Wien] -eece and -hf switch for hybrid functionals

2012-08-12 Thread ali ghafari
Dear Prof. Blaha
Thank you very much for replay. 

As I understand from UG (page 68 ) in the last step of Self-consistent 
calculation for full hybrids
we should use -hf and -eece together i.e run(sp)_ lapw -hf -eece ...
?Is it right??
Best Regards
Ali




 From: Peter Blaha pblaha at theochem.tuwien.ac.at
To: A Mailing list for WIEN2k users wien at zeus.theochem.tuwien.ac.at 
Sent: Sunday, August 12, 2012 7:26 PM
Subject: Re: [Wien] -eece and -hf switch for hybrid functionals
 
No, full hybrids are not supported in w2web. You have to use the command line 
and
follow the procedures indicated in the UG.

Am 12.08.2012 15:52, schrieb ali ghafari:
 Dear Prof. Blaha and users

 In the page 68 of UG, it has mentioned that for using hybrid functionals such 
 as B3LYP we should use
 -hf switch while at the w2web only -eece is possible. Could you please tell 
 me when we select -eece switch
 it automatically add -hf switch? or we should only use -hf at the terminal?

 Best Regards
 Ali


 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien


-- 
-
Peter Blaha
Inst. Materials Chemistry, TU Vienna
Getreidemarkt 9, A-1060 Vienna, Austria
Tel: +43-1-5880115671
Fax: +43-1-5880115698
email: pblaha at theochem.tuwien.ac.at
-
___
Wien mailing list
Wien at zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
-- next part --
An HTML attachment was scrubbed...
URL: 
http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20120812/9f79c6a9/attachment.htm