[Wien] Re : error lapw1 unit 18

2012-05-20 Thread Gavin Abo
The error message can not open unit 18 seems incomplete.

I can only guess that maybe you mixed a non-spin polarized and spin 
polarized run.

See: http://zeus.theochem.tuwien.ac.at/pipermail/wien/2010-June/013366.html

You can also find some other posts on the unit 18 error by older 
archives search at: http://www.wien2k.at/reg_user/mailing_list/

On 5/20/2012 3:39 PM, Mouna Mesbahi wrote:
 hello;
 Please I have a system in which I have a nickel atom (transition 
 material) in the optimization stage I afffiche error in lapw1 (can not 
 open unit 18) how to solve this problem please
 thank you in advance
 cordially mouna

 *De :* Mouna Mesbahi mouna.mesbahi at yahoo.fr
 *? :* wien at zeus.theochem.tuwien.ac.at wien at 
 zeus.theochem.tuwien.ac.at
 *Envoy? le :* Vendredi 20 janvier 2012 13h36
 *Objet :*

 I have already tried the dituted semicondictors please i want to ask 
 you if it is obliged to pass by the generation of supercelle to add 
 the impurity
 thank you in advance
 cordially mouna Mesbahi




 ___
 Wien mailing list
 Wien at zeus.theochem.tuwien.ac.at
 http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien

-- next part --
An HTML attachment was scrubbed...
URL: 
http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20120520/7343/attachment-0001.htm


[Wien] Re : error lapw1 unit 18

2012-05-20 Thread Laurence Marks
A more general comment. As described in the user guide, for every command
there is a .def file, for instance lapw1.def or uplapw1.def. This file is
created by the x command. If you read the relevant .def file you will see
that it has the unit number as well as the file name. You can then track
back to what is wrong, perhaps as Gavin says mixing spin and no spin.

You can do the same for all commands. It is a good learning experience to
look, and also look and understand what the x command is doing.

---
Professor Laurence Marks
Department of Materials Science and Engineering
Northwestern University
www.numis.northwestern.edu 1-847-491-3996
Research is to see what everybody else has seen, and to think what nobody
else has thought
Albert Szent-Gyorgi
 On May 20, 2012 8:43 PM, Gavin Abo gsabo at crimson.ua.edu wrote:

  The error message can not open unit 18 seems incomplete.

 I can only guess that maybe you mixed a non-spin polarized and spin
 polarized run.

 See:
 http://zeus.theochem.tuwien.ac.at/pipermail/wien/2010-June/013366.html

 You can also find some other posts on the unit 18 error by older
 archives search at: http://www.wien2k.at/reg_user/mailing_list/

 On 5/20/2012 3:39 PM, Mouna Mesbahi wrote:

  hello;
 Please I have a system in which I have a nickel atom (transition material)
 in the optimization stage I afffiche error in lapw1 (can not open unit 18) how
 to solve this problem please
 thank you in advance
 cordially mouna

   *De :* Mouna Mesbahi mouna.mesbahi at yahoo.fr mouna.mesbahi at yahoo.fr
 *? :* wien at zeus.theochem.tuwien.ac.at wien at 
 zeus.theochem.tuwien.ac.at
 wien at zeus.theochem.tuwien.ac.at wien at zeus.theochem.tuwien.ac.at
 *Envoy? le :* Vendredi 20 janvier 2012 13h36
 *Objet :*

   I have already tried the dituted semicondictors please i want to ask
 you if it is obliged to pass by the generation of supercelle to add the
 impurity
 thank you in advance
 cordially mouna Mesbahi




 ___
 Wien mailing listWien at 
 zeus.theochem.tuwien.ac.athttp://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien



-- next part --
An HTML attachment was scrubbed...
URL: 
http://zeus.theochem.tuwien.ac.at/pipermail/wien/attachments/20120520/121c049f/attachment.htm