Re: [Wien] core hole in high energy level

2019-07-01 Thread Peter Blaha

What one can do is a "2-window" calculation with "semicore states.
You divide your electronic states into semicore and valence, such that 
the state you want to calculate is the highest semicore state.


Then you create case.in1sc and case.in2sc with NE(sc)=NE(sc)-1/2.

In case.in2 you would change Emin such that you cut away these semicore 
states and add 1/2 electron to NE to compensate for the hole.


Be careful with this and watch the scf carefully if the cutoff energies 
are working and :NEC01 is ok.


Special tricks have to be made when MULT > 1 to make them inequivalent, 
but in addition the state with the hole will go down in energy and no 
longer at the "top" of the semicore bands, so one needs tricks (either 
with case.inst or using LDA+U) to seperate this state such that it is 
"top of semicore", while the full semicore states should go into the 
valence window.


Eventually, it would also help to first create a real core-hole (setting 
E-cut higher than the 6 eV and neglecting the core leakage). Once you 
have a decent scf-potential with the core hole, you can do the 
"semicore" 2-window calculation as indicated above.


Regards

Am 30.06.2019 um 15:02 schrieb Lyudmila Dobysheva:

Dear WIEN-users,

How to calculate the high-lying energy level in XPS (close to valence 
band, less than the standard 6 Ry)?
To put the core hole, the only way that I know is to change the 6 Ry to 
a less value and move the level from the semi-core (valence) to the core.

Is it correct?

Best regards
Lyudmila Dobysheva
--
Physics-Techn.Institute,
Udmurt Federal Research Center, Ural Br. of Rus.Ac.Sci.
426000 Izhevsk Kirov str. 132
Russia
---
Tel. +7 (34I2)43-24-59 (office), +7 (9I2)OI9-795O (home)
Skype: lyuka18 (office), lyuka17 (home)
E-mail: lyuk...@mail.ru (office), lyuk...@gmail.com (home)
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


--
--
Peter BLAHA, Inst.f. Materials Chemistry, TU Vienna, A-1060 Vienna
Phone: +43-1-58801-165300 FAX: +43-1-58801-165982
Email: bl...@theochem.tuwien.ac.atWIEN2k: http://www.wien2k.at
WWW: 
http://www.imc.tuwien.ac.at/tc_blaha- 


___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


Re: [Wien] core hole in high energy level

2019-06-30 Thread Laurence Marks
If you interpret +U as a Slater-Janek method (see DOI:
10.1103/PhysRevMaterials.2.025001 and references therein), you can use it
to estimate the effect fairly well.

On Sun, Jun 30, 2019 at 2:05 PM Lyudmila Dobysheva  wrote:

> Dear WIEN-users,
>
> How to calculate the high-lying energy level in XPS (close to valence
> band, less than the standard 6 Ry)?
> To put the core hole, the only way that I know is to change the 6 Ry to
> a less value and move the level from the semi-core (valence) to the core.
> Is it correct?
>
> Best regards
> Lyudmila Dobysheva
> --
> Physics-Techn.Institute,
> Udmurt Federal Research Center, Ural Br. of Rus.Ac.Sci.
> 426000 Izhevsk Kirov str. 132
> Russia
> ---
> Tel. +7 (34I2)43-24-59 (office), +7 (9I2)OI9-795O (home)
> Skype: lyuka18 (office), lyuka17 (home)
> E-mail: lyuk...@mail.ru (office), lyuk...@gmail.com (home)
> ___
> Wien mailing list
> Wien@zeus.theochem.tuwien.ac.at
>
> https://urldefense.proofpoint.com/v2/url?u=http-3A__zeus.theochem.tuwien.ac.at_mailman_listinfo_wien=DwICAg=yHlS04HhBraes5BQ9ueu5zKhE7rtNXt_d012z2PA6ws=U_T4PL6jwANfAy4rnxTj8IUxm818jnvqKFdqWLwmqg0=chLasXOzKupXvZ_pqjhmpub252M-ddPXBDnKBfJtz90=FPKO5X9Pfujxmalscx06wovFjVmi5AxgkjA2xzqWcrA=
> SEARCH the MAILING-LIST at:
> https://urldefense.proofpoint.com/v2/url?u=http-3A__www.mail-2Darchive.com_wien-40zeus.theochem.tuwien.ac.at_index.html=DwICAg=yHlS04HhBraes5BQ9ueu5zKhE7rtNXt_d012z2PA6ws=U_T4PL6jwANfAy4rnxTj8IUxm818jnvqKFdqWLwmqg0=chLasXOzKupXvZ_pqjhmpub252M-ddPXBDnKBfJtz90=G5WLven5-LhNcgUH3dMOc7_gFy-tcLaio7q5ft_XLHA=
>


-- 
Professor Laurence Marks
Department of Materials Science and Engineering
Northwestern University
www.numis.northwestern.edu
Corrosion in 4D: www.numis.northwestern.edu/MURI
Co-Editor, Acta Cryst A
"Research is to see what everybody else has seen, and to think what nobody
else has thought"
Albert Szent-Gyorgi
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html


[Wien] core hole in high energy level

2019-06-30 Thread Lyudmila Dobysheva

Dear WIEN-users,

How to calculate the high-lying energy level in XPS (close to valence 
band, less than the standard 6 Ry)?
To put the core hole, the only way that I know is to change the 6 Ry to 
a less value and move the level from the semi-core (valence) to the core.

Is it correct?

Best regards
Lyudmila Dobysheva
--
Physics-Techn.Institute,
Udmurt Federal Research Center, Ural Br. of Rus.Ac.Sci.
426000 Izhevsk Kirov str. 132
Russia
---
Tel. +7 (34I2)43-24-59 (office), +7 (9I2)OI9-795O (home)
Skype: lyuka18 (office), lyuka17 (home)
E-mail: lyuk...@mail.ru (office), lyuk...@gmail.com (home)
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
SEARCH the MAILING-LIST at:  
http://www.mail-archive.com/wien@zeus.theochem.tuwien.ac.at/index.html