There is no independent greed (the correct term for the mixing
parameter) for the magnetic moment in Wien2k. While some codes might
use one, it is really not justifiable in the quasi-Newton mathematics.
On Mon, Sep 9, 2013 at 7:16 AM, nju...@sina.com wrote:
>
> Hi everybody:
> there is density mixing parameter, but I don't find the parameter about
> magnetic moment.
>
>
--
Professor Laurence Marks
Department of Materials Science and Engineering
Northwestern University
www.numis.northwestern.edu 1-847-491-3996
"Research is to see what everybody else has seen, and to think what
nobody else has thought"
Albert Szent-Gyorgi
___
Wien mailing list
Wien@zeus.theochem.tuwien.ac.at
http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien