what are you using is : Onsiteexact-exchange as mentionned in the UG : Onsiteexact-exchange will NOT improve gaps in sp-semiconductors. page 48
you MUST use Unscreened and screened hybrid functionals 4.5.8 page 49 in the UG Regards abdel Date: Thu, 4 Apr 2013 12:16:52 +0530 From: dashora...@gmail.com To: Wien@zeus.theochem.tuwien.ac.at Subject: [Wien] Error while using Hybrid functional Dear Wien2k Users, I am running Wien2k calculation for semiconductor compound Cu2ZnSiS4. Using mbj potential, the band gap was very low as compared to the expt. value. So I have decided to use hybrid functional. I have used the following steps: 1. run: runsp_lapw -p (scf completed without any error) with PBE-sol functional 2. made case.ineece file as follows: -9.0 3 1 1 2 2 1 2 3 1 2 HYBR 0.253. run: runsp_lapw -eece -p at the end of first cycle following error was occur ORB END ORB END set: no matchNo error file was generated. I am enclosing herewith the structure file also. Kindly suggest me, how to remove this error. With kind regards, -- Alpa Dashora _______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien
_______________________________________________ Wien mailing list Wien@zeus.theochem.tuwien.ac.at http://zeus.theochem.tuwien.ac.at/mailman/listinfo/wien