Q223757….

 

We were apparently using a value (ReplicationSourceDC in this case) that does not get read during a demotion, only during promotions.

 

Larry A. Duncan, MCSA/MCSE

Directory Services Engineer/

Systems Management Consultant

[EMAIL PROTECTED]

ph. 615.598.0241

 

-----Original Message-----
From: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]] On Behalf Of Larry A. Duncan
Sent:
Friday, November 08, 2002 10:31 AM
To: [EMAIL PROTECTED]
Subject: [ActiveDir] DCPromo w/ Answer File

 

We are processing some 230 DCs for demotion over the weekend. To facilitate this, we’ve created an answer file that specifies that the ReplicationSourceDC is to use during the demotion. But, during the demotion, we’re seeing it not use the named source. Any suggestions?

 

 

Larry A. Duncan, MCSA/MCSE

Directory Services Engineer/

Systems Management Consultant

[EMAIL PROTECTED]

ph. 615.598.0241

 