Re: [AMRadio] B&K 1602 Power Supply question

2005-03-20 Thread Geoff
Mahlon Haunschild wrote: > Hello, list. Have acquired a B&K 1602 HV power supply. Basic problem is no C- voltage (that's the one intended for use as a bias supply, I believe). Internal inspection of the unit's pc board reveals that R33 is burned beyond recognition and Q3 is GONE (well, the

[AMRadio] B&K 1602 Power Supply question

2005-03-19 Thread Mahlon Haunschild
Hello, list. Have acquired a B&K 1602 HV power supply. Basic problem is no C- voltage (that's the one intended for use as a bias supply, I believe). Internal inspection of the unit's pc board reveals that R33 is burned beyond recognition and Q3 is GONE (well, the lead frame is there, but the