We experienced this phenomenon on a 120 seat IP430 deployment last
year. It ended up being a firmware concern. We worked directly with
PolyCom engineering to get a B rev of the firmware at that time out to
address the problem. Bring everything up to the most recent bootrom
and firmware
)
+1.215.243.8335 (fax)
- Original Message -
From: bob murphy
To: Commercial and Business-Oriented Asterisk Discussion
Sent: Thursday, February 07, 2008 9:56 AM
Subject: [asterisk-biz] (((Polycom Reboot)))
We have two larger deployments (150 extensions and 400 respectively) and
Polycom
POE. If you plug the AC adapter into the phone it won't reboot.
bob murphy wrote:
We have two larger deployments (150 extensions and 400 respectively) and
Polycom IP550 and IP430 are rebooting intermittently. Very strange.
Anyone ever see this? It's not all the phones just random groups
We have two larger deployments (150 extensions and 400 respectively) and
Polycom IP550 and IP430 are rebooting intermittently. Very strange. Anyone
ever see this? It's not all the phones just random groups of them. The
only other common element is HP procurve LAN switches. Any hunches out