We've changed E1 providers and I'm trying to reconfigure an E400P to
make it work with the new lines. They're supposedly standard EuroISDN
lines (in the UK). I'm initially just trying to get a single line up.
I have the following in /etc/zaptel.conf:
span=1,0,0,ccs,hdb3
bchan=1-15
If your proider is using a System-X switch don't bother
the e400p does not work correctly with those, you need a te410p
and your problem sounds like that. the e400p has a framer that is not
compatible with some switches.
sorry to tell yoyu that
Michael
On Friday 12 September 2003 5:43 pm,
Try adding ,crc4 to the end of the span definition.
Mark
On Fri, 12 Sep 2003, Alastair Maw wrote:
We've changed E1 providers and I'm trying to reconfigure an E400P to
make it work with the new lines. They're supposedly standard EuroISDN
lines (in the UK). I'm initially just trying to get a
OK, so I've done this:
*CLI pri intense debug span 1
Enabled EXTENSIVE debugging on span 1
Sending Set Asynchronous Balanced Mode Extended
[00 01 7f ]
Unnumbered frame:
SAPI: 00 C/R: 0 EA: 0
TEI: 000EA: 1
M3: 3 P/F: 1 M2: 3 11: 3 [ SABME ]
0 bytes of data
So you don't receive any answer from the other side ?
Is the circuit in alarm ? Can they do remote loopup test ?
It might be that they don't have their D-channel turned on ...
Martin
On Fri, 12 Sep 2003, Alastair Maw wrote:
OK, so I've done this:
*CLI pri intense debug span 1