Re: [Asterisk-Users] McLeod Integrated T1 - no PRI?

2005-07-11 Thread Kristian Kielhofner
qrss wrote: Does anyone have any ideas? Any magic words to give to the people at McLeod to get this running? You might ask the carrier to take a careful look at the mapping for the d-channel in their DACS equipment and perhaps even ask them to try re-mapping it for you. If that does not get t

Re: [Asterisk-Users] McLeod Integrated T1 - no PRI?

2005-07-09 Thread Andy Brezinsky
We have a McLeod T1 and they told us specifically that it was a PRI, ended up being em_wink. Make sure they really have it setup right. -- ~Andy Brezinsky On Friday 08 July 2005 5:45 pm, Kristian Kielhofner wrote: > Hello everyone, > > We have recently turned up a new T1 from McLeod (Mid

Re: [Asterisk-Users] McLeod Integrated T1 - no PRI?

2005-07-08 Thread qrss
>Does anyone have any ideas? Any magic words to give to the people at >McLeod to get this running? You might ask the carrier to take a careful look at the mapping for the d-channel in their DACS equipment and perhaps even ask them to try re-mapping it for you. If that does not get things moving,

Re: [Asterisk-Users] McLeod Integrated T1 - no PRI?

2005-07-08 Thread Kristian Kielhofner
Chris Shaw wrote: **Snip** pbx*CLI> pri show span 1 Primary D-channel: 24 Status: Provisioned, Down, Active Switchtype: National ISDN Type: CPE Window Length: 0/7 Sentrej: 0 SolicitFbit: 0 Retrans: 0 Busy: 0 Overlap Dial: 0 T200 Timer: 1000 T203 Timer: 1 T305 Timer: 3 T308 Timer: 4000 T3

RE: [Asterisk-Users] McLeod Integrated T1 - no PRI?

2005-07-08 Thread Chris Shaw
**Snip** pbx*CLI> pri show span 1 Primary D-channel: 24 Status: Provisioned, Down, Active Switchtype: National ISDN Type: CPE Window Length: 0/7 Sentrej: 0 SolicitFbit: 0 Retrans: 0 Busy: 0 Overlap Dial: 0 T200 Timer: 1000 T203 Timer: 1 T305 Timer: 3 T308 Timer: 4000 T313 Timer: 4000 N200

[Asterisk-Users] McLeod Integrated T1 - no PRI?

2005-07-08 Thread Kristian Kielhofner
Hello everyone, We have recently turned up a new T1 from McLeod (Midwestern CLEC). It is configured like so: /etc/zaptel.conf: loadzone=us defaultzone=us span=1,0,0,esf,b8zs ;(also tried 1,1,0,esf,b8zs) bchan=13-23 nethdlc=1-12 dchan=24 /etc/zapata.conf: switchtype=national context=pri-i