In fact, with EWSD V13 you can't remove CRC4 in PRI mode.
Regards,
Gus
- Original Message -
From: Storer, Darren [EMAIL PROTECTED]
To: [EMAIL PROTECTED]
Sent: Wednesday, April 07, 2004 8:32 PM
Subject: RE: [Asterisk-Users] Siemens EWSD 13
Hi,
I had exactly the same symptoms today
Hi all,
Has anyone got any experience with hooking Asterisk up with a
Siemens EWSD 13 switch over a E1/PRI ?
We're located in Belgium (Europe) and one of our telecom partners
uses this switch.
We connected one of our TE410P ports with their switch, but the status
light on the TE410P card keeps
Hi,
If you didnt do it yet I'd suggest you start with simpliest thing which is
making loop on the cables. And testing the status. Simple RJ45 plug with
10cm of 2 pairs of cable crimped by 1,2 on 4,5.
When you make loop T410P goes green. EWSD also will see a loop.
Check cables and loops and when
TelcoInternetBroadcast
-Original Message-
From: [EMAIL PROTECTED]
[mailto:[EMAIL PROTECTED] Behalf Of
[EMAIL PROTECTED]
Sent: 07 April 2004 14:59
To: [EMAIL PROTECTED]
Subject: [Asterisk-Users] Siemens EWSD 13
Hi all,
Has anyone got any experience with hooking Asterisk up with a
Siemens