Hi Venu, I have bit confused with your question. What is the error you exactly get?. If the string value is null that seems it is correct. Because you set the String as null and it is an OUT parameter.
Actually the OUT parameter means, in wsdl If a part name appears in only the output message, it is an out parameter. You check your wsdl whether the String is an OUT parameter or not.(You can check it in the part name.If it only occurs in the out message then only it will be a OUT parameter). I think it is right when it is an OUT parameter.(String is null). You better set a value to that String and check it whether it works. Hope it would help you a bit. regards, Jeyakumaran > Guys, > > I am having issues to retrieve the output > parameters(ParameterMode.OUT/ParameterMode.INOUT) after calling invoke > (). > > Appreciate if anyone can tell me what I am doing wrong or point me to a > sample code. > > Thanks a ton, > Venu. > > > > My code looks as follows: > > Service service = new Service(); > Call perCall = (Call) service.createCall(); > QName personqn = new QName( "urn:DBInsertService", > "Person" > ); > > perCall.registerTypeMapping(Person.class, personqn, > new > org.apache.axis.encoding.ser.BeanSerializerFactory(Person.class, > personqn), > new > org.apache.axis.encoding.ser.BeanDeserializerFactory(Person.class, > personqn)); > > perCall.setTargetEndpointAddress( new java.net.URL(endpoint) ); > perCall.setOperationName( new QName("DBInsertService", > "insertPerson" > ) ); > perCall.addParameter( "person", personqn, ParameterMode.IN ); > perCall.addParameter( "serviceTimes", XMLType.XSD_STRING, > ParameterMode.OUT ); > perCall.setReturnType( XMLType.XSD_BOOLEAN ); // set > return type > > Person dbP = new Person(); > String str = null; // also tried with new, the result was that > there was no value. > > // This method sets the result to str; > boolean l_result = ((Boolean)perCall.invoke(new Object[] {dbP, > str})).booleanValue(); > > System.out.println("Output: " + str); // this line showed up > str as > null. > > _____________________________________________________ > SIEMENS Medical Solutions - Health Services > Venu Ambekar > Software Engineer, DC6 - Architecture > 51 Valley Stream Parkway, Malvern, PA, 19355-1406 > Phone: +01 610 219 7982 > Fax: +01 610 219 8470 > E-Mail: [EMAIL PROTECTED] > _______________________________________________________ > > > > ------------------------------------------------------------------------------- > This message and any included attachments are from Siemens Medical > Solutions USA, Inc. and are intended only for the addressee(s). > The information contained herein may include trade secrets or privileged > or otherwise confidential information. Unauthorized review, > forwarding, printing, copying, distributing, or using such information > is strictly prohibited and may be unlawful. If you received this > message in error, or have reason to believe you are not authorized to > receive it, please promptly delete this message and notify the sender > by e-mail with a copy to [EMAIL PROTECTED] Thank you