Re: [Bacula-users] [Bacula-devel] Bacula BETA version 2.5.16 released

2008-10-24 Thread Jesper Krogh
Kern Sibbald wrote: > Hello, > > We have released Bacula BETA version 2.5.16 source tar file and Win32 > binaries > to the bacula-beta and win32-beta sections of the Bacula Source Forge > download area. > > This is our first beta version of the new development code, which we hope to > release

Re: [Bacula-users] [Bacula-devel] Bacula BETA version 2.5.16 released

2008-10-24 Thread Kern Sibbald
On Friday 24 October 2008 09:05:27 Jesper Krogh wrote: > Kern Sibbald wrote: > > Hello, > > > > We have released Bacula BETA version 2.5.16 source tar file and Win32 > > binaries to the bacula-beta and win32-beta sections of the Bacula Source > > Forge download area. > > > > This is our first beta

Re: [Bacula-users] [Bacula-devel] Bacula BETA version 2.5.16 released

2008-10-24 Thread Jesper Krogh
Kern Sibbald wrote: > On Friday 24 October 2008 09:05:27 Jesper Krogh wrote: >> Kern Sibbald wrote: >>> Hello, >>> >>> We have released Bacula BETA version 2.5.16 source tar file and Win32 >>> binaries to the bacula-beta and win32-beta sections of the Bacula Source >>> Forge download area. >>> >>>

[Bacula-users] First use of volumes

2008-10-24 Thread Kshatriya
Hello ! Maybe I don't know where to find it in Bacula and it already exists, but a feature I've always 'missed' is that Bacula doesn't save the date of the first use of a volume (and optionally the read/write count). It would be very nice to know this, because then you know how old your tapes

[Bacula-users] Why isn't bacula asking for a tape from the pool?

2008-10-24 Thread Bill Damage
Hi, well its happened, I did ask about this on this list a while back and thought it was sorted. I only have 10 tapes in my pool. I set up a daily incremental, and identified the pool to have 10 in. It worked fine and each time a change was needed I labelled them on the fly, like 002, 003 etc. I

Re: [Bacula-users] Why isn't bacula asking for a tape from the pool?

2008-10-24 Thread Bruno Friedmann
Bill Damage wrote: > Hi, well its happened, I did ask about this on this list a while back and > thought it was sorted. I only have 10 tapes in my pool. I set up a daily > incremental, and identified the pool to have 10 in. It worked fine and each > time a change was needed I labelled them on th

Re: [Bacula-users] Why isn't bacula asking for a tape from the pool?

2008-10-24 Thread John Drescher
On Fri, Oct 24, 2008 at 7:18 AM, Bill Damage <[EMAIL PROTECTED]> wrote: > Hi, well its happened, I did ask about this on this list a while back and > thought it was sorted. I only have 10 tapes in my pool. I set up a daily > incremental, and identified the pool to have 10 in. It worked fine and eac

Re: [Bacula-users] First use of volumes

2008-10-24 Thread Timo Neuvonen
"Kshatriya" <[EMAIL PROTECTED]> kirjoitti viestissä:[EMAIL PROTECTED] > Hello ! > > Maybe I don't know where to find it in Bacula and it already exists, but a > feature I've always 'missed' is that Bacula doesn't save the date of > the first use of a volume (and optionally the read/write count). >

Re: [Bacula-users] Why isn't bacula asking for a tape from the pool?

2008-10-24 Thread Bill Damage
Thanks, and to Bruno. Yes I'd forgotten I left the default when setting up the pool. Ok now. From: John Drescher <[EMAIL PROTECTED]> To: Bill Damage <[EMAIL PROTECTED]>; "Bacula-users@lists.sourceforge.net" Sent: Friday, October 24, 2008 12:57:04 PM Subject: R

[Bacula-users] InChanger flag not reset

2008-10-24 Thread LeJav
Hello, I am using bacula-2.4.3-1 I have autochanger (HP MSL2024) with barcodes. tapes are labeled with "label barcode" everything is working well, but if i remove a tape from the library and do not replace it with a new tape, the old volume has not its 'InChanger' flag reset. This causes a l

Re: [Bacula-users] InChanger flag not reset

2008-10-24 Thread ebollengier
Hello, Yes, it seems to be a bug (or an unwanted feature). Please, can you open a bug in bugs.bacula.org ? A simple workaround is put an other volume in the empty slot, or to update the volume with something like "update volume=xxx inchanger=0". Bye LeJav wrote: > > Hello, > > I am using ba

Re: [Bacula-users] InChanger flag not reset

2008-10-24 Thread LeJav
even "update volume=xxx inchanger=0" does not work > Hello, > > Yes, it seems to be a bug (or an unwanted feature). Please, can you open a > bug > in bugs.bacula.org ? > > A simple workaround is put an other volume in the empty slot, or to update > the volume with something like "update vol