Op 20120902 om 09:53 schreef Michael D. Wood:
> From: lst_ho...@kwsoft.de [mailto:lst_ho...@kwsoft.de]
> Sent: Friday, August 31, 2012 4:31 PM
> > Zitat von "Michael D. Wood" :
> >
> > > Has anyone else ran across this issue?
> > >
> > > Faulting application bat.exe, version 0.0.0.0, time stamp 0
On 09/03/12 18:50, Steve Costaras wrote:
>
> when I had problems here, I also did not see hard errors w/ application code,
> just slow performance (70MB/s or so). When I ran the manufacturer's drive
> test code it did show up internal issues (compression/crc/etc not withing
> manufacturer spe
when I had problems here, I also did not see hard errors w/ application code,
just slow performance (70MB/s or so). When I ran the manufacturer's drive
test code it did show up internal issues (compression/crc/etc not withing
manufacturer specs).
Not saying that this is your problem at all
On 09/03/12 17:26, Steve Costaras wrote:
>
> Would also verify your drive. I've had issues with LTO drives that just
> flake out over time and required replacement from the vendors in the past.
> Most vendors supply a test utility.
Running a btape write test right this moment. (And for the
Would also verify your drive. I've had issues with LTO drives that just flake
out over time and required replacement from the vendors in the past. Most
vendors supply a test utility.
As for the block size limit increase, that's not correct. Even though it was
stated in the change logs tha
>> My company has 2 LTO4 autochanger tape libraries (1 drive per
>> library, 20TB max per library).
>> Size to backup is about 30TB.
>>
I would divide this job down into much smaller chunks if possible.
>> As backup size does not fit a single library, I simply would like to
>> span my storage usi
Zitat von Vincent Miszczak :
> Hi guys,
>
> I'm looking at Bacula for future backup software for my company.
> I've already use it for simple cases, and now I'm looking to use it
> in production.
>
> My company has 2 LTO4 autochanger tape libraries (1 drive per
> library, 20TB max per library
On 09/03/12 11:51, Phil Stracchino wrote:
> All of a sudden, my Bacula-5.2.10 storage daemon keeps crashing with the
> following error reported:
Preliminary analysis at this point appears to indicate that it is a
REALLY bad idea on an LTO drive to have bacula-sd's configured max block
size not an
All of a sudden, my Bacula-5.2.10 storage daemon keeps crashing with the
following error reported:
warning: Could not load shared library symbols for linux-vdso.so.1.
Do you need "set solib-search-path" or "set sysroot"?
[Thread debugging using libthread_db enabled]
[New Thread 0x7f8c66ffd700 (LW
Hi guys,
I'm looking at Bacula for future backup software for my company.
I've already use it for simple cases, and now I'm looking to use it in
production.
My company has 2 LTO4 autochanger tape libraries (1 drive per library, 20TB max
per library).
Size to backup is about 30TB.
As backup siz
On Thu, Aug 30, 2012 at 12:01 PM, Rao, Uthra R. (GSFC-672.0)[ADNET
SYSTEMS INC] wrote:
>
> John,
>
> I wanted to try something to get my 2TB tapes recycle faster.
>
> Current configuration:
>
> pool {
> name = server-archive
> Pool Type = Backup
> Autoprune = no
> Recycle = no
> Volume R