Re: [Bacula-users] frequent segfaults

2017-01-27 Thread Craig Shiroma
Hi All, Thank you very much for all the help! Sorry for the delayed reply. What I've done so far is move the Director VM to a different ESXi host. So far, no segfaults although I'll give it a week before raising the all clear flag. There are normally many VMs on the ESXi host that the Director

Re: [Bacula-users] frequent segfaults

2017-01-27 Thread Josh Fisher
On 1/27/2017 4:04 AM, Craig Shiroma wrote: Hi All, Thank you very much for all the help! Sorry for the delayed reply. What I've done so far is move the Director VM to a different ESXi host. So far, no segfaults although I'll give it a week before raising the all clear flag. Are the VM'

Re: [Bacula-users] btape multivolume fill test fails on 7.4.4 but succeeds on 5.2.13

2017-01-27 Thread Alan Brown
On 27/01/17 00:36, Caribe Schreiber wrote: > Hi all, > > I'm hoping someone can help point me in the right direction to get the > btape multivolume fill test to work under bacula-7.4.4. You can't. It's broken. It was fixed recently but that fix hasn't rolled into the public release stream yet (a

Re: [Bacula-users] btape multivolume fill test fails on 7.4.4 but succeeds on 5.2.13

2017-01-27 Thread Caribe Schreiber
That's sad to hear, but I'm glad to know that it's got a known issue that's being worked on. I've tried the single volume test with similar results (see below). Is the breakage only in the multivolume test, or is the btape fill facility just plain broken in 7.4.4? Thanks for your help! --

Re: [Bacula-users] frequent segfaults

2017-01-27 Thread Craig Shiroma
Hi Josh, >Are the VM's configured exactly the same on both ESXi hosts? A difference in VCPU, memory limit, etc. in the VM config could potentially reveal the problem. The VM that bacula-dir is running on is configured exactly the same. No changes were made to it before I vMotioned it to a differ