[OSL | CCIE_Voice] Question for lab

2013-01-08 Thread Abdullin Kamil
Hi men, I have question: During lab, tasks are provided in electronic form or on paper? -- ___ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com Are you a CCNP or CCIE and looking for a job? Check out www

[OSL | CCIE_Voice] VOL2 lab 1 - HQ Phone cannot register ? WTH

2013-01-08 Thread Nicolas MICHEL
Hey guys. I m in trouble with the phone connected to Fa1/0/23 of the 3750 in HQ. Vlan assignement are OK: HQ-3750#sh run int fa1/0/23 Building configuration... Current configuration : 113 bytes ! interface FastEthernet1/0/23 switchport access vlan 10 switchport voice vlan 20 spanning-tree po

Re: [OSL | CCIE_Voice] VOL2 lab 1 - HQ Phone cannot register ? WTH

2013-01-08 Thread Mohammed Nabelsi
It might be IP dhcp snooping... On Tue, Jan 8, 2013 at 7:57 AM, Nicolas MICHEL wrote: > Hey guys. > > I m in trouble with the phone connected to Fa1/0/23 of the 3750 in HQ. > > Vlan assignement are OK: > HQ-3750#sh run int fa1/0/23 > Building configuration... > > Current configuration : 113 byt

[OSL | CCIE_Voice] CME-Unity Connection integration using Skinny

2013-01-08 Thread Suresh Bhandari
I am trying to integrate CME to UCx using Skinny but I am stuck with the "Failed to send message to remote AXL server. " message. I have in Phone System CUCM AXL Servers the IP of the CME and the https port (443), ip http secure-server enabled, xml username/pwd set, ixi transport and application

Re: [OSL | CCIE_Voice] VOL2 lab 1 - HQ Phone cannot register ? WTH

2013-01-08 Thread William Bell
Nic, On your HQ router, can you check Fa0/0.10? Make sure you have the following config: encapsulation dot1q 10 native I don't think it is DHCP snooping or you would not receive an IP address. However, you could (and should) Erase the config on the IP phone to ensure it isn't just using an "

[OSL | CCIE_Voice] CME-Unity Connection integration using Skinny

2013-01-08 Thread Chrysostomos Christofi
check this doc http://www.cisco.com/en/US/docs/voice_ip_comm/connection/7x/integration/cucme_sccp/guide/cucintcucmesccp050.html But its much easier with sip integration dial-peer voice 3 voip description voice mail pilot max-conn 8 destination-pattern (voicemail number session protocol si

Re: [OSL | CCIE_Voice] CME-Unity Connection integration using Skinny

2013-01-08 Thread Suresh Bhandari
I had already followed that, and my bad that I was stuck in where I wanted to get the users from CME to UCx! Its done. Thanks again. On Tue, Jan 8, 2013 at 10:55 PM, Chrysostomos Christofi < ch.christ...@logicom.net> wrote: > check this doc > > > http://www.cisco.com/en/US/docs/voice_ip_

Re: [OSL | CCIE_Voice] VOL2 lab 1 - HQ Phone cannot register ? WTH

2013-01-08 Thread Steffen Bruening
Hi Nicolas, I had this problem too on some pods, where only one of the HQ phones want to register, same for site B, dhcp addressing is working but no registration occurs. Because I had no physical access on the phones to check what the display is showing ( I guess something like registration rejec

Re: [OSL | CCIE_Voice] Auto QoS is not working on INE Rack Rentals

2013-01-08 Thread Marko Milivojevic
Hesham, Please OSL is a support list owned and operated by IPexpert. Please refrain from discussing our competitors' products and services here. Thank you. -- Marko Milivojevic - CCIE #18427 (SP R&S) Senior CCIE Instructor - IPexpert On Tue, Jan 8, 2013 at 10:04 AM, Hesham Abdelkereem wrote: >

[OSL | CCIE_Voice] DIAL PLAN - Numbering Plan Query

2013-01-08 Thread ie ravindra
Hi All, What is the idea behind of numbering plan, Such as ISDN , NATIONAL , etc. How it can be applied in real world. Thanks, IE. ___ For more information regarding industry leading CCIE Lab training, please visit www.ipexpert.com Are you a CCNP or C

[OSL | CCIE_Voice] MWI off for broadcast message is not working.

2013-01-08 Thread CCIEing
Hi All, I configured a user in the CUE to send broadcast message, he is able to send the message, the MWI ON appear on the phone, but when recipient hear the broadcast message and the message deleted, the red alarm and the envelop does not disappear , the MWI OFF is not working, until I perform th

Re: [OSL | CCIE_Voice] MWI off for broadcast message is not working.

2013-01-08 Thread CCIEing
Guys Seems that I am asking, then I can find an answer to my questions, :) I find the following cisco document : * http://www.cisco.com/en/US/docs/voice_ip_comm/unity_exp/design/design21/cuevmdes.html#wp1008620 * Which says clearly that "WI operation for broadcast messaging cannot be controlled p

Re: [OSL | CCIE_Voice] VOL2 lab 1 - HQ Phone cannot register ? WTH

2013-01-08 Thread Nicolas MICHEL
Hi Guys ! Yeah I have checked fa0/0.10 and it is ok ! I cannot access to the IP phone since it is PL facilities :) DHCP scope has been created/deleted/checked etc etc I had no problem with BR1 or BR2 ... only with the 7962 in HQ .. Weird ! I have the same rack tomorrow for the same lab (VOL2

[OSL | CCIE_Voice] Connection Monitor Duration for SRST testing

2013-01-08 Thread Pixar Perfect
Hello, is it advisable to bring down the Connection Monitor Duration under Device Pool to a low value like 30 seconds to expedite the SRST testing in the lab? Does it affect grading if we happen to put it back to default? thx ___

[OSL | CCIE_Voice] Gatekeeper in Single zone : Call Processing engine prioritize

2013-01-08 Thread Ramcharan Arya
Hello, I have a small query about Gatekeeper in single zone configuration it is prefer PUB as call processing ( as per ARQ message). if lab requirement says make subscriber as call processing engine then it does not meet requirement. Does any one know the answer what is the solution of this tric

Re: [OSL | CCIE_Voice] VOL2 lab 1 - HQ Phone cannot register ? WTH

2013-01-08 Thread Piotr Puchalski
Nic, I’ve been battling a somewhat similar problem in my own lab (I have all the hardware on my rack with full access) and the problem was that somehow one of the phones was not taking the default gateway set in PUB’s DHCP. I configured a pool locally on the router and it worked then. Next day

Re: [OSL | CCIE_Voice] Remote access on lab.

2013-01-08 Thread Steffen Bruening
Both is available on the desktop (in Brussels) Am Mittwoch, 9. Januar 2013 schrieb Abdullin Kamil : > Hi men, > On lab what program is used for remote access on UCCX? > windows remote desktop, VNC or any other? > Thanks! > > > ___ For more information r

Re: [OSL | CCIE_Voice] Gatekeeper in Single zone : Call Processing engine prioritize

2013-01-08 Thread Steffen Bruening
You can define a gw-priority for the trunks to each endpoint. Am Mittwoch, 9. Januar 2013 schrieb Ramcharan Arya : > Hello, > > I have a small query about Gatekeeper in single zone configuration it is > prefer PUB as call processing ( as per ARQ message). > > if lab requirement says make subscrib

Re: [OSL | CCIE_Voice] Connection Monitor Duration for SRST testing

2013-01-08 Thread Steffen Bruening
I always put it down to 10s, not less because sometimes the wan connection is flapping/very low and so the phones flapping between cucm and srst. Am Mittwoch, 9. Januar 2013 schrieb Pixar Perfect : > Hello, > > is it advisable to bring down the Connection Monitor Duration under Device > Pool to