We are having 2811 for lab practice.
 
In HQ site alone, I have configured IOS transcoder and using MRGL I have update 
where ever we need transcoder.
 
Now my problem is from FXS 212x, I am not able to call SITE-B 300x number from 
212x,
if I configure transcoder in site-b I am able to make call from 212x to site-b
 
Do you have any suggestion without configuring IOS transcoder in SITE-B, we can 
not call 3001 from HQ FXS.
 
Thanks
 