On Dec 4th last year I asked for recommendations for a UV
spectrophotometer to determine the concentration of protein/ [RD]NA
samples.
I received an enormous amount of answer emails, both to the board and
privately and I am trying to summarise them as good as possible.
We finally decided
hello all,
I would like to thank everyone for all suggestions.
Summary:
1 - MiTeGen Tools - MicroRTâ„¢ Room Temperature Mounting System
- crystals slipping ? (suggestion of juan: amongst other things, problem
resolved by using micromesh loops instead of using standard loops)
- uses
We have both LED and cold light sources attached to our Zeiss Stemi
microscopes on the beamlines at Diamond. There was some argument about
not using LED lights however the solution from Zeiss is very good
allowing different sections of LEDs to be used which can be moved
around. This allows crystal
We are collecting information on computer platforms that people would
like ARP/wARP to run on. To access the questionnaire please go to
http://www.embl-hamburg.de/ARP/platinf_new.shtml
Thank you for your cooperation.
With best regards,
Victor
BEAM TIME AVAILABLE FOR MACROMOLECULAR CRYSTALLOGRAPHY AT THE TWO ID
BEAMLINES OF NE-CAT AT APS.
Beamline 24ID-C: Variable energy between 6-18keV, ADSC Q315 Detector, MAD
Capable.
Beamline 24ID-E: Equipped with MD2 microdiffractometer, delivering beam as
small as 5 microns. Single energy
If you will use the Nextal device, I have also modified it something
like fig.2 for checking crystals in the drop at room temperature. It
is not difficult to make, too. Please see,
http://journals.iucr.org/j/issues/2005/02/00/he5324/he5324bdy.html
However, getting the film I have used in the
Dear all,
I tried to build CCP4 6.1 with Intel Compiler Intel Math Kernel
Library(MKL) on Fedora 8. I used MKL as LAPACK and FFTW libraries. The
building processes have been completed successfully, but all tests
passed except cbuccaneer.exam (core dumped).
Log: ---
% ./cbuccaneer.exam or make
Dear Nobuo:
I should let the experts answer definitively, but I think this might
be because the clipper-related stuff (and coot) need single-precision
s[r]fftw libraries.
I had to do something like this:
LDFLAGS=-Wl,-dylib_file,/sw/lib/libsfftw.2.0.7.dylib:/sw/lib/
libsrfftw.2.0.7.dylib
Stereo 3D Users:
I tested out the Samsung Syncmaster 2233RZ / NVIDIA 3D Vision bundle
today ($599 for a 120 Hz LCD display with one pair of glasses).
Unfortunately, the 2233RZ display is clearly not yet a drop-in
replacement for your stereo-3D-capable CRT: The display is very nice,
and the