Sorry Marc, didn't see second question.
As the upgrade process states, rgw are the last one to be upgraded, so
they are still on nautilus (centos7). Those logs showed up after upgrade
of the first osd host. It is a multisite setup so I am a little afraid
of upgrading rgw now.
Etienne:
I did it only on MON servers. OSDs are on centos 7. Process was:
1. stop mon
2. backup /var/lib/ceph
3. reinstall server as centos 8 and install ceph nautilus
4. restore /var/lib/ceph and start mo
5. wait few days
6. upgrade mon to octopus
On 20.10.2021 o 09:51, Marc wrote:
How did you do the
Yes I did, and despite "Too many repaired reads on 1 OSDs" health is
back to HEALTH_OK.
But it is second time it happened and do not know, should I go forward
with update or hold on. Or maybe it is a bad move makeing compaction
right after migration to 15.2.14
On 20.10.2021 o 09:21, Szabo,