Hi,
I created a secondary zone where the placement maps to an EC pool. 2 zones are
under the same zonegroup and same cluster. But the secondary zone or EC pool
did not receive any data (only user info is synced). So how do you make it
work? Thanks
___
On 10/29/19 1:40 AM, Mac Wynkoop wrote:
So, I'm in the process of trying to migrate our rgw.buckets.data pool
from a replicated rule pool to an erasure coded pool. I've gotten the
EC pool set up, good EC profile and crush ruleset, pool created
successfully, but when I go to "rados cppool xxx.rg
We've solved this off-list (because I already got access to the cluster)
For the list:
Copying on rados level is possible, but requires to shut down radosgw
to get a consistent copy. This wasn't feasible here due to the size
and performance.
We've instead added a second zone where the placement m
RADOS import/export? Will look into that. I ended up going with Paul's
suggestion, and created a separate zone under the main zonegroup with
another RGW instance running that zone, and had it sync the data into the
Erasure-Coded zone. Made it very easy to do!
Thanks,
Mac
On Wed, Oct 30, 2019 at