[ceph-users] Re: OSD's still UP after power loss

2021-05-21 Thread Eugen Block
Is there any better solution? Yes, add more nodes. ;-) Having only two OSD nodes is not the best idea, it's kind of a corner case and I've observed some weird behaviour with corner cases in the past, not even mentioning the 2 replicas. Is this a test environment? Zitat von by morphin :

[ceph-users] Re: OSD's still UP after power loss

2021-05-21 Thread by morphin
I've figured out but I'm scared from the result. The solution is "mon_osd_min_down_reporters = 1" Due to "two node" cluster and "replicated 2" with "chooseleaf host" the reporter count should be set to 1 but on a malfunction this could be a serious problem. Is there any better solution? by