[ceph-users] Re: PGS INCONSISTENT - read_error - replace disk or pg repair then replace disk

2020-05-23 Thread Anthony D'Atri
Historically I have often but not always found that removing / destroying the affected OSD would clear the inconsistent PG. At one point the logged message was clear about who reported and who was the perp, but then a later release broke that. Not sure what recent releases say, since with Lumi

[ceph-users] Re: PGS INCONSISTENT - read_error - replace disk or pg repair then replace disk

2020-05-23 Thread Massimo Sgaravatto
When I see this problem usually: - I run pg repair - I remove the OSD from the cluster - I replace the disk - I recreate the OSD on the new disk Cheers, Massimo On Wed, May 20, 2020 at 9:41 PM Peter Lewis wrote: > Hello, > > I came across a section of the documentation that I don't quite > un