On Mon, Jul 22, 2013 at 08:45:07AM +1100, Mikaël Cluseau wrote:
> On 22/07/2013 08:03, Charles 'Boyo wrote:
> >Counting on the kernel's cache, it appears I will be best served
> >purchasing write-optimized SSDs?
> >Can you share any information on the SSD you are using, is it PCIe
> >connected?
>
On 22/07/2013 08:03, Charles 'Boyo wrote:
Counting on the kernel's cache, it appears I will be best served
purchasing write-optimized SSDs?
Can you share any information on the SSD you are using, is it PCIe
connected?
We are on a standard SAS bus so any SSD going to 500MB/s and being
stable o
On 07/21/13 20:37, Wido den Hollander wrote:
I'd saw two disks and not raid0. Since when you are doing parallel I/O
both disks can be doing something completely different.
Completely agree, Ceph is already doing the stripping :)
___
ceph-users mailin
Hello.
I am intending to build a Ceph cluster using several Dell C6100 multi-node
chassis servers.
These have only 3 disk bays per node (12 x 3.5" drives across 4 nodes) so I
can't afford to sacrifice a third of my capacity for SSDs. However, fitting the
SSD via PCI-e seems a valid option.
Un
Hi again,
[root@xen-blade05 ~]# virsh pool-info rbd
Name: rbd
UUID: ebc61120-527e-6e0a-efdc-4522a183877e
State: running
Persistent: no
Autostart: no
Capacity: 5.28 TiB
Allocation: 16.99 GiB
Available: 5.24 TiB
I managed to get it running. How
Hi,
thanks a lot for your answer. I was successfully able to create the
storage pool with virsh.
However it is not listed when I issue a virsh pool-list:
Name State Autostart
-
If I try to add it again:
[root@xen-blade05 ~]# virsh
On 07/20/2013 11:42 PM, Wido den Hollander wrote:
On 07/20/2013 05:16 PM, Sage Weil wrote:
On Sat, 20 Jul 2013, Wido den Hollander wrote:
On 07/20/2013 06:56 AM, Jeffrey 'jf' Lim wrote:
On Fri, Jul 19, 2013 at 12:54 PM, Jeffrey 'jf' Lim
wrote:
hey folks, I was hoping to be able to use xfs on
Hi,
On 07/21/2013 08:14 AM, Sébastien RICCIO wrote:
Hi !
I'm currently trying to get the xenserver on centos 6.4 tech preview
working against a test ceph cluster and having the same issue.
Some infos: the cluster is named "ceph", the pool is named "rbd".
ceph.xml:
rbd
ceph
Hi,
On 07/21/2013 07:20 AM, James Harper wrote:
I have a server with 2 x 2TB disks. For performance, is it better to combine
them as a single OSD backed by RAID0 or have 2 OSD's backed by a single disk?
(log will be on SSD in either case).
I'd saw two disks and not raid0. Since when you are
Hi,
Rgw bucket index is in one file (one osd performance issues).
Is there on roudmap sharding or other change to increase performance?
--
Pozdrawiam
Dominik
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-u
I have a server with 2 x 2TB disks. For performance, is it better to combine
them as a single OSD backed by RAID0 or have 2 OSD's backed by a single disk?
(log will be on SSD in either case).
My need in performance is more IOPS than overall throughput (maybe that's a
universal thing? :)
Thanks
11 matches