Hi Irek,
Thanks for the link. I have removed the SSD's for now and performance is up to
30MB/s on a benchmark now. To be honest, I new the Samsung SSD weren't great
but did not expect them to be worse then just plain hard disks.
Pieter
On Aug 12, 2015, at 01:09 PM, Irek Fasikhov
4.0.6-300.fc22.x86_64
On Tue, Aug 11, 2015 at 10:24 PM, Yan, Zheng uker...@gmail.com wrote:
On Wed, Aug 12, 2015 at 5:33 AM, Hadi Montakhabi h...@cs.uh.edu wrote:
[sequential read]
readwrite=read
size=2g
directory=/mnt/mycephfs
ioengine=libaio
direct=1
blocksize=${BLOCKSIZE}
Здравствуйте!
On Wed, Aug 12, 2015 at 02:30:59PM +, pieter.koorts wrote:
Hi Irek,
Thanks for the link. I have removed the SSD's for now and performance is up
to 30MB/s on a benchmark now. To be honest, I new the Samsung SSD weren't
great but did not expect them to be worse then just
Hi,
for mds there is the ability to rename snapshots. But for rbd i can't
see one.
Is there a way to rename a snapshot?
Greets,
Stefan
___
ceph-users mailing list
ceph-users@lists.ceph.com
http://lists.ceph.com/listinfo.cgi/ceph-users-ceph.com
Hi all, we have setup CEPH cluster with 60 OSD (2 diff types) (5 nodes, 12
disks on each, 10 HDD, 2 SSD)
Also we cover this with custom crushmap with 2 root leaf
ID WEIGHT TYPE NAME UP/DOWN REWEIGHT PRIMARY-AFFINITY
-100 5.0 root ssd
-102 1.0 host ix-s2-ssd
2
I ran a ceph osd reweight-by-utilization yesterday and partway through
had a network interruption. After the network was restored the cluster
continued to rebalance but this morning the cluster has stopped
rebalance and status will not change from:
# ceph status
cluster
If I am using a more recent client(kernel OR ceph-fuse), should I still be
worried about the MDS's crashing? I have added RAM to my MDS hosts and its
my understanding this will also help mitigate any issues, in addition to
setting mds_bal_frag = true. Not having used cephfs before, do I always
I also encounter a problem,standby mds can not be altered to active when active
mds service stopped,which bother me for serval days.Maybe MDS cluster can solve
those problem,but ceph team haven't released this feature.
yangyongp...@bwstor.com.cn
From: Yan, Zheng
Date: 2015-08-13 10:21
To:
On Wed, Aug 12, 2015 at 7:21 PM, Yan, Zheng uker...@gmail.com wrote:
On Thu, Aug 13, 2015 at 7:05 AM, Bob Ababurko b...@ababurko.net wrote:
If I am using a more recent client(kernel OR ceph-fuse), should I still
be
worried about the MDS's crashing? I have added RAM to my MDS hosts and
On Thu, Aug 13, 2015 at 7:05 AM, Bob Ababurko b...@ababurko.net wrote:
If I am using a more recent client(kernel OR ceph-fuse), should I still be
worried about the MDS's crashing? I have added RAM to my MDS hosts and its
my understanding this will also help mitigate any issues, in addition to
On Wed, Aug 12, 2015 at 5:08 AM, Bob Ababurko b...@ababurko.net wrote:
What is risky about enabling mds_bal_frag on a cluster with data and will
there be any performance degradation if enabled?
No specific gotchas, just that it is not something that has especially
good coverage in our automated
Jörg Henne hennejg@... writes:
we are running ceph version 0.94.2 with a cephfs mounted using ceph-fuse on
Ubuntu 14.04 LTS. I think we have found a bug that lets us semi-reprodicibly
crash the ceph-fuse process.
Reported as http://tracker.ceph.com/issues/12674
Hello.
Could you please help me to remove osd from cluster;
# ceph osd tree
ID WEIGHT TYPE NAME UP/DOWN REWEIGHT PRIMARY-AFFINITY
-1 0.02998 root default
-2 0.00999 host ceph1
0 0.00999 osd.0 up 1.0 1.0
-3 0.00999 host ceph2
1 0.00999
An update:
It seems that I am arriving at memory shortage. Even with 32 GB for 20
OSDs and 2 GB swap, ceph-osd uses all available memory.
I created another swap device with 10 GB, and I managed to get the
failed OSD running without crash, but consuming extra 5 GB.
Are there known issues
If you are using the default configuration to create the pool (3 replicas),
after losing 1 OSD and having 2 left, CRUSH would not be able to find enough
OSDs (at least 3) to map the PG thus it would stuck at unclean.
Thanks,
Guang
From:
Hi Igor
I suspect you have very much the same problem as me.
https://www.mail-archive.com/ceph-users@lists.ceph.com/msg22260.html
Basically Samsung drives (like many SATA SSD's) are very much hit and miss so
you will need to test them like described here to see if they are any good.
I tried it, the error propagates to whichever OSD gets the errorred PG.
For the moment, this is my worst problem. I have one PG
incomplete+inactive, and the OSD with the highest priority in it gets
100 blocked requests (I guess that is the maximum), and, although
running, doesn't get other
Hi.
Read this thread here:
https://www.mail-archive.com/ceph-users@lists.ceph.com/msg17360.html
С уважением, Фасихов Ирек Нургаязович
Моб.: +79229045757
2015-08-12 14:52 GMT+03:00 Pieter Koorts pieter.koo...@me.com:
Hi
Something that's been bugging me for a while is I am trying to diagnose
Hi
Something that's been bugging me for a while is I am trying to diagnose iowait
time within KVM guests. Guests doing reads or writes tend do about 50% to 90%
iowait but the host itself is only doing about 1% to 2% iowait. So the result
is the guests are extremely slow.
I currently run 3x
Hi,
I would like to hear from people who use cache tier in Ceph about best
practices and things I should avoid.
I remember hearing that it wasn't that stable back then. Has it changed in
Hammer release?
Any tips and tricks are much appreciated!
Thanks
Dominik
-Original Message-
From: ceph-users [mailto:ceph-users-boun...@lists.ceph.com] On Behalf Of
Dominik Zalewski
Sent: 12 August 2015 14:40
To: ceph-us...@ceph.com
Subject: [ceph-users] Cache tier best practices
Hi,
I would like to hear from people who use cache tier in Ceph about
There currently is no mechanism to rename snapshots without hex editing the RBD
image header data structure. I created a new Ceph feature request [1] to add
this ability in the future.
[1] http://tracker.ceph.com/issues/12678
--
Jason Dillaman
Red Hat Ceph Storage Engineering
Yeah. You are right. Thank you.
On Aug 12, 2015, at 19:53, GuangYang yguan...@outlook.com wrote:
If you are using the default configuration to create the pool (3 replicas),
after losing 1 OSD and having 2 left, CRUSH would not be able to find enough
OSDs (at least 3) to map the PG thus
23 matches