Re: [ceph-users] How to attach permission policy to user?

2019-03-11 Thread myxingkong
Hi Pritha: I added administrator quotas to users, but they didn't seem to work. radosgw-admin user create --uid=ADMIN --display-name=ADMIN --admin --system radosgw-admin caps add --uid="ADMIN" --caps="user-policy=*;roles=*;users=*;buckets=*;metadata=*;usage=*;zone=*" {     "user_id":

Re: [ceph-users] How to attach permission policy to user?

2019-03-11 Thread Pritha Srivastava
Hi Myxingkong, Did you add admin caps to the user (with access key id 'HTRJ1HIKR4FB9A24ZG9C'), which is trying to attach a user policy. using the command below: radosgw-admin caps add --uid= --caps="user-policy=*" Thanks, Pritha On Tue, Mar 12, 2019 at 7:19 AM myxingkong wrote: > Hi Pritha:

Re: [ceph-users] How to attach permission policy to user?

2019-03-11 Thread myxingkong
Hi Pritha: I was unable to attach the permission policy through S3curl, which returned an HTTP 403 error. ./s3curl.pl --id admin -- -s -v -X POST

Re: [ceph-users] 3-node cluster with 3 x Intel Optane 900P - very low benchmarked performance (200 IOPS)?

2019-03-11 Thread David Clarke
On 9/03/19 10:07 PM, Victor Hooi wrote: > Hi, > > I'm setting up a 3-node Proxmox cluster with Ceph as the shared storage, > based around Intel Optane 900P drives (which are meant to be the bee's > knees), and I'm seeing pretty low IOPS/bandwidth. We found that CPU performance, specifically

[ceph-users] Is repairing an RGW bucket index broken?

2019-03-11 Thread Bryan Stillwell
I'm wondering if the 'radosgw-admin bucket check --fix' command is broken in Luminous (12.2.8)? I'm asking because I'm trying to reproduce a situation we have on one of our production clusters and it doesn't seem to do anything. Here's the steps of my test: 1. Create a bucket with 1 million

[ceph-users] Chasing slow ops in mimic

2019-03-11 Thread Alex Litvak
Hello Cephers, I am trying to find the cause of multiple slow ops happened with my small cluster. I have a 3 node with 9 OSDs Intel(R) Xeon(R) CPU E5-2650 v4 @ 2.20GHz 128 GB RAM Each OSD is SSD Intel DC-S3710 800GB It runs mimic 13.2.2 in containers. Cluster was operating normally for 4

Re: [ceph-users] 3-node cluster with 3 x Intel Optane 900P - very low benchmarked performance (200 IOPS)?

2019-03-11 Thread Vitaliy Filippov
These options aren't needed, numjobs is 1 by default and RBD has no "sync" concept at all. Operations are always "sync" by default. In fact even --direct=1 may be redundant because there's no page cache involved. However I keep it just in case - there is the RBD cache, what if one day fio

Re: [ceph-users] 3-node cluster with 3 x Intel Optane 900P - very low benchmarked performance (200 IOPS)?

2019-03-11 Thread solarflow99
how about adding: --sync=1 --numjobs=1 to the command as well? On Sat, Mar 9, 2019 at 12:09 PM Vitaliy Filippov wrote: > There are 2: > > fio -ioengine=rbd -direct=1 -name=test -bs=4k -iodepth=1 -rw=randwrite > -pool=bench -rbdname=testimg > > fio -ioengine=rbd -direct=1 -name=test -bs=4k

Re: [ceph-users] radosgw sync falling behind regularly

2019-03-11 Thread Trey Palmer
HI Casey, We're still trying to figure this sync problem out, if you could possibly tell us anything further we would be deeply grateful! Our errors are coming from 'data sync'. In `sync status` we pretty constantly show one shard behind, but a different one each time we run it. Here's a

Re: [ceph-users] priorize degraged objects than misplaced

2019-03-11 Thread Fabio Abreu
I am looking one problematic pg on my disaster scenario and look at bellow : root@monitor~# ceph pg ls-by-pool cinder_sata | grep 5.5b7 5.5b7 26911 29 53851 107644 29 11224818892853258 53258 active+recovering+undersized+degraded+remapped 2019-03-11 14:05:29.857657

[ceph-users] Host-local sub-pool?

2019-03-11 Thread Harry G. Coin
Hello all I have a 'would be nice' use case need I'm wondering if ceph can handle.  The goal is to allow an otherwise ordinary ceph server with a little 'one-of' special purpose extra hardware that could provide at least some value when off-host networking is down to do so while still taking

Re: [ceph-users] how to identify pre-luminous rdb images

2019-03-11 Thread Denny Kreische
> Am 11.03.2019 um 12:21 schrieb Konstantin Shalygin : > > >> Hello list, >> >> I upgraded to mimic some time ago and want to make use of the upmap feature >> now. >> But I can't do "ceph osd set-require-min-compat-client luminous" as there >> are still pre-luminous clients connected. >>

Re: [ceph-users] SSD OSD crashing after upgrade to 12.2.10

2019-03-11 Thread Eugen Block
Hi all, we had some assistance with our SSD crash issue outside of this mailing list - which is not resolved yet (http://tracker.ceph.com/issues/38395) - but there's one thing I'd like to ask the list. I noticed that a lot of the OSD crashes show a correlation to MON elections. For the

Re: [ceph-users] How to just delete PGs stuck incomplete on EC pool

2019-03-11 Thread Maks Kowalik
Hello Daniel, I think you will not avoid a tedious job of manual cleanup... Or the other way is to delete the whole pool (ID 18). The manual cleanup means to take all the OSDs from "probing_osds", stop them one by one and remove the shards of groups 18.1e and 18.c (using ceph-objstore-tool).

Re: [ceph-users] OpenStack with Ceph RDMA

2019-03-11 Thread Lazuardi Nasution
Hi David, I know the different between cluster network and public network. I usually split them to vlans for statistic, isolation and priority. What I need to know is about what kind of RDMA messaging Ceph do. Is it between OSDs or related to other daemons and clients too? Best regards, On

Re: [ceph-users] OpenStack with Ceph RDMA

2019-03-11 Thread David Turner
I can't speak to the rdma portion. But to clear up what each of these does... the cluster network is only traffic between the osds for replicating writes, reading EC data, as well as backfilling and recovery io. Mons, mds, rgw, and osds talking with clients all happen on the public network. The

Re: [ceph-users] priorize degraged objects than misplaced

2019-03-11 Thread David Turner
Ceph has been getting better and better about prioritizing this sorry of recovery, but free of those optimizations are in Jewel, which had been out of the support cycle for about a year. You should look into upgrading to mimic where you should see a pretty good improvement on this sorry of

Re: [ceph-users] CEPH ISCSI Gateway

2019-03-11 Thread David Turner
The problem with clients on osd nodes is for kernel clients only. That's true of krbd and the kernel client for cephfs. The only other reason not to run any other Ceph daemon in the same node as osds is resource contention if you're running at higher CPU and memory utilizations. On Sat, Mar 9,

Re: [ceph-users] how to identify pre-luminous rdb images

2019-03-11 Thread Konstantin Shalygin
Hello list, I upgraded to mimic some time ago and want to make use of the upmap feature now. But I can't do "ceph osd set-require-min-compat-client luminous" as there are still pre-luminous clients connected. The cluster was originally created from jewel release. When I run "ceph features", I

Re: [ceph-users] How to attach permission policy to user?

2019-03-11 Thread Pritha Srivastava
Hi Myxingkong, http://docs.ceph.com/docs/nautilus/mgr/restful/ is for the Manager module of ceph. This is not related to rgw. Please try attaching a policy by configuring s3curl tool. Thanks, Pritha On Mon, Mar 11, 2019 at 3:43 PM myxingkong wrote: > Hi Pritha: > > This is the documentation

Re: [ceph-users] How to attach permission policy to user?

2019-03-11 Thread myxingkong
Hi Pritha:This is the documentation for configuring restful modules:http://docs.ceph.com/docs/nautilus/mgr/restful/The command given according to the official documentation is to attach the permission policy through the REST API.This is the documentation for STS

Re: [ceph-users] How to attach permission policy to user?

2019-03-11 Thread Pritha Srivastava
Hi Myxingkong, Can you explain what you mean by 'enabling restful modules', particularly which document are you referring to? Right now there is no other way to attach a permission policy to a user. There is work in progress for adding functionality to RGW using which such calls can be scripted

[ceph-users] how to identify pre-luminous rdb images

2019-03-11 Thread Denny Kreische
Hello list, I upgraded to mimic some time ago and want to make use of the upmap feature now. But I can't do "ceph osd set-require-min-compat-client luminous" as there are still pre-luminous clients connected. The cluster was originally created from jewel release. When I run "ceph features", I

[ceph-users] How to attach permission policy to user?

2019-03-11 Thread myxingkong
Hello:I want to use the GetSessionToken method to get the temporary credentials, but according to the answer given in the official documentation, I need to attach a permission policy to the user before I can use the GetSessionToken method.This is the command for the additional

Re: [ceph-users] REQUEST_SLOW across many OSDs at the same time

2019-03-11 Thread mart.v
Well, the drive supports trim: # hdparm -I /dev/sdd|grep TRIM            *    Data Set Management TRIM supported (limit 8 blocks)            *    Deterministic read ZEROs after TRIM But fstrim or discard is not enabled (I have checked both mount options and services/cron). I'm using

Re: [ceph-users] Ceph crushmap re-arrange with minimum rebalancing?

2019-03-11 Thread Wido den Hollander