RE: CFMX7 and COM

2005-06-08 Thread Paolo Piponi
If anyone does have any ideas, I'd love to hear them. In the meantime I shall backup the current configuration and return to 5. :o( Thanks, Paolo > -Original Message- > From: George Abraham [mailto:[EMAIL PROTECTED] > Sent: 07 June 2005 18:03 > To: CF-Talk > Subject:

RE: CFMX7 and COM

2005-06-07 Thread Mark A Kruger
al Message- From: Paolo Piponi [mailto:[EMAIL PROTECTED] Sent: Tuesday, June 07, 2005 11:54 AM To: CF-Talk Subject: CFMX7 and COM I am currently testing an upgrade from CF5 to CFMX7 and all went well except a major component of our website that uses COM. In accessing the COM with code that works

Re: CFMX7 and COM

2005-06-07 Thread George Abraham
What object are you trying to instantiate? Does the account under which CFMX runs (usually system account) have permissions to access the COM object or to instantiate it? George On 6/7/05, Paolo Piponi <[EMAIL PROTECTED]> wrote: > I am currently testing an upgrade from CF5 to CFMX7 and all went w

CFMX7 and COM

2005-06-07 Thread Paolo Piponi
I am currently testing an upgrade from CF5 to CFMX7 and all went well except a major component of our website that uses COM. In accessing the COM with code that works fine in CF 5 we get: "An exception occurred when instantiating a Com object. The cause of this exception was that: AutomationEx