Matthieu,
The blocks must be sent sequentially in order, from the upstream partner to the
downstream partner. The first block contains the staging header and the first
part of the staging file data. A later block must not be processed unless the
previous block has been downloaded successfully,
[Dochelp to bcc]
Thanks Matthieu for this input, I will investigate and follow up.
Regards,
Edgar
-Original Message-
From: Matthieu Patou [mailto:m...@samba.org]
Sent: Tuesday, September 20, 2011 3:48 PM
To: Edgar Olougouna; Interoperability Documentation Help; p...@tridgell.net;
cifs-
Hello Edgar,
Initial testing seems to indicate that when trying to install a staged
file FRS obey to lock. It might help you to orientate your work.
Matthieu.
On 20/09/2011 13:45, Edgar Olougouna wrote:
[Bcc Bryan]
Matthieu,
I am taking care of these questions. I will update you as soon as
Hi Hongwei,
On 19/09/2011 18:47, Hongwei Sun wrote:
Hi, Matthieu,
The bit 0x80 should be CO_FLAG_INSTALL_INCOMPLETE that means local install
has not been completed. With the value is 0xC6 , this flag is shown to be
used on wire, we need to add this flag to the section 2.2.3.2 of MS-FRS1