Guys,
Is there a way to configure a 10/100 port on a Cat switch as MDI X (cross
connect). So that we can use straight cable to connect two switches...
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7i=70109t=70109
--
FAQ, list
NM-4T1-IMA requires IP Plus feature set
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7i=69952t=69793
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure
To bring up both B- channels set
dialer load threshold 5 .
and if you want to test it usean extended ping with bigger packet size that
will help.
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7i=69953t=69737
--
FAQ, list
Run the Debug PPP that will help to locate the problem
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7i=69951t=69951
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and
fixed it, all the unused ports need to be in loopback mode
otherwise the card shows alarm!!!
sumitsood wrote in message
news:[EMAIL PROTECTED]
It is 7204VXR running 12.2.15B
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7i=65711t=65540
It is 7204VXR running 12.2.15B
Message Posted at:
http://www.groupstudy.com/form/read.php?f=7i=65621t=65540
--
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to
Hi,
we have a new PRI card PA-MC-8TE1+
The alarm light stays on the card as soon as you plug it in any port on
7204.
We have tried replacing the card, but the newer card also had the same prob.
Any Suggestions/Experience??
Sumit
Message Posted at:
7 matches