Elijah,

    What kind of GBICs are you using?  If they're LX and MM fiber, are you
using mode-conditioning cables?

Chuck Church
CCIE #8776, MCNE, MCSE

>
From: Elijah Savage [mailto:[EMAIL PROTECTED]
Sent: Friday, February 28, 2003 8:27 AM
To: [EMAIL PROTECTED]
Subject: FCS Errors between 2 5500's [7:64072]


All,



Last night I had to shutdown a gig fiber trunk between 2 5500's to run
on a 100M trunk we setup as a backup. The FCS errors are only showing up
on one side the fiber between the 2 cats were replaced but the errors
are still showing up. Which side would you all say you would replace the
fiber daughter card the one with the errors or the side without the
errors?




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=64180&t=64180
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to