Help !!! [7:72096]

2003-07-10 Thread H T
what does it mean? and Why I am getting this message? TestR(config-line)#autoselect ppp %Autoselect w/o the interface command 'Async mode interactive' is useless Cheers Message Posted at: http://www.groupstudy.com/form/read.php?f=7i=72096t=72096

Re: Help !!! [7:72096]

2003-07-10 Thread AK
the line must be n interective mode if u want the user to select the proto or the AS to autosence the proto used based on there flags. u just need to put the line in interactive mode b4 the autoselect command, that's it, cause in dedicated mode the line is simply bound to the proto defined. H T

RE: Help !!! [7:72096]

2003-07-10 Thread George Murage
] Sent: Thursday, July 10, 2003 2:11 PM To: [EMAIL PROTECTED] Subject: Help !!! [7:72096] what does it mean? and Why I am getting this message? TestR(config-line)#autoselect ppp %Autoselect w/o the interface command 'Async mode interactive' is useless Cheers Message Posted at: http

RE: Help !!! [7:72096]

2003-07-10 Thread Michael F.
HI, I found the following Answer somewhere on the CISCO TAC : If you issue the autoselect ppp line configuration command, you must first issue the async mode interactive asynchronous interface configuration command. The async mode interactive command enables the interface to select a protocol