3524 .try it.
Ouellette, Tim wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
Team,
can anyone help out. I am seeing the following messages on one of our
6509's. Port 7/2 is connected via fiber to a 3524 closet switch. We've
tried replacing the gbic's on both the 6509 and
Tim,
I've had a similar problem in the past between a 5500 and 6509. It was a
bad blade in the 5500.
R/
Dave
On 4/8/02 10:54 PM, in article [EMAIL PROTECTED],
Ouellette, Tim wrote:
Team,
can anyone help out. I am seeing the following messages on one of our
6509's. Port 7/2 is
: [EMAIL PROTECTED] [mailto:[EMAIL PROTECTED]]On Behalf Of
yangchun
Sent: Monday, April 08, 2002 11:07 PM
To: [EMAIL PROTECTED]
Subject: Re: 6509 trunk to 3524? Any suggestions [7:40876]
3524 .try it.
Ouellette, Tim wrote in message
[EMAIL PROTECTED]">news:[EMAIL PROTECTED]...
Team,
You cant use dtp with 3524, use the
set trunk */* nonegoitate dot1q to force it to trunk...
Also make sure you enble on the ge 0/1 on the 3524 as a switch port mode
trunk with dot1q encapsulation
That will force it to trunk, and life will be sweet. We use Dual 6509's with
10 3548XLs and its
[mailto:[EMAIL PROTECTED]]
Sent: Monday, April 08, 2002 11:41 PM
To: [EMAIL PROTECTED]
Subject: RE: 6509 trunk to 3524? Any suggestions [7:40876]
Tim,
This should do it for you
http://www.cisco.com/warp/public/473/43.html
It appears that you didn't disable trunk negotiation on the 6500. Since
5 matches
Mail list logo