RE: Frame Relay DLCIs [7:14717]

2001-08-03 Thread Erick B.
Here's whats-what for DLCIs. 0 - inband sig/mgmt (Annex A Q.933, Annex D T1.617) 1-15 - reserved 16-991 - assignable to user connections 992-1007 - level 2 management 1008-1022 - reserved (carrier-provided multicasting) 1023 - inband sig/mgmt (LMI Rev 1, gang of four) HTH, Erick --- Chuck Larr

Re: Frame Relay DLCIs [7:14717]

2001-08-15 Thread suaveguru
Yes you can use any digits provided they are not reserved DLCIs regards, suaveguru --- "Provost, Robert" wrote: > What numbers can you use for DLCIs? I have always > seen three digit DLCI > numbers. Can they be one digit? two? four? five? > > Thanks, > Rob [EMAIL PROTECTED]

Re: Frame Relay DLCIs [7:14717]

2001-08-15 Thread Dennis H
No you can not use any digits. I don't remember exactly but I think the valid range is 17-1027... Dennis ""suaveguru"" wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... > Yes you can use any digits provided they are not > reserved DLCIs > > regards, > suaveguru > --- "Provost, Rob

Re: Frame Relay DLCIs [7:14717]

2001-08-15 Thread Neil Schneider
IIRC its 0-1023, but 0-16? are reserved as is 1023. Neil ""Dennis H"" wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECTED]... > No you can not use any digits. I don't remember exactly but I think the > valid range is 17-1027... > > Dennis > > > ""suaveguru"" wrote in message > [EMAIL P

Re: Frame Relay DLCIs [7:14717]

2001-08-26 Thread David L. Blair
Range of numbers 0 - 1023. Reserved numbers: 0, 1005 - 1023. I have also heard that 992 to 1004 is reserved. So that would make valid range either 1 - 1004 or 1 - 991. "Through Complexity there is Simplicity, Through Simplicity there is Complexity" David L. Bl