RE: Mfsc [7:26752]

2001-11-19 Thread Georgescu, Aurelian
Yes it is possible. You must have Sup 2 and MSFC2 to do this. Is called "Single Router Mode". If only Sup 1 is available, you can configure "high availability" feature and use "alternate" command in the primary router configuration. AG -Original Message- From: James L Williams [mailto:[

Re: Mfsc [7:26752]

2001-11-19 Thread MADMAN
see config-sync: http://www.cisco.com/univercd/cc/td/doc/product/lan/cat6000/sft_6_1/configgd/redund.htm#xtocid2195532 Dave James L Williams wrote: > > Is their a way to have redundant MSFC's on the same switch sync their > config's the same way redundant supervisor engines sync their config

Re: Mfsc [7:26752]

2001-11-19 Thread Jeff D
You can actually use ConfigSyn with Sup1/MSFC1 or Sup2/MSFC2.. I've got both configured and it works great... make sure you're running at least 12.1(8)E5 on MSFC2 though as I have run into some bugs with 12.1(7)E. Jeff ""James L Williams"" wrote in message [EMAIL PROTECTED]">news:[EMAIL PROTECT