Re: S.Singh: Faulty Serial Link [7:35379]

2002-02-14 Thread PING
If you see, interface up/line protocol down, most common cause is encapsulation mismatch or clocking problem. With serial it is usually clocking and DCE/DTE issue. You should duble check that and also the interface statistics. Nadeem == dr_sukhi wrote Respected Seniors and Friends in the

Re: Re: S.Singh: Faulty Serial Link [7:35379]

2002-02-14 Thread dr_sukhi
Thanks Nadeem, one thing more, when the serial interface goes down, the LED hangs, i.e. even when I remove the serial cable does the LED keep glowing. Only when I restart the router does the LED status come to actual. Can you add to this? I'll tell you the end results of this case, keep checking

S.Singh: Faulty Serial Link [7:35379]

2002-02-13 Thread dr_sukhi
Respected Seniors and Friends in the group, In Cisco 2620 router, I have configured 2 WIC-A/S cards for three 64k leased lines. All worked until all stopped working suddenly. Other ports, ISDN etc. are fine. Serial lines show LINE PROTOCOL DOWN. When I reboot the router one card starts working,