Hi group, I have set CAR on one of my sub-interfaces on my 3661 router, the problem is that it only limits the OUTPUT packets. Here are my configs:
interface FastEthernet0/0.3 description 32/128 kbps test encapsulation isl 3 ip address 213.217.37.245 255.255.255.252 no ip redirects no ip directed-broadcast rate-limit input 32000 8000 8000 conform-action transmit exceed-action drop rate-limit output 128000 8000 8000 conform-action transmit exceed-action drop end And bellow are the results when I stated pinging (ping -f ) a host on VLAN 3 (213.217.37.246) from my linux server Router#sh int rate-limit FastEthernet0/0.3 32/128 test Input matches: all traffic params: 32000 bps, 8000 limit, 8000 extended limit conformed 0 packets, 0 bytes; action: transmit exceeded 0 packets, 0 bytes; action: drop last packet: 1867294456ms ago, current burst: 0 bytes last cleared 00:32:57 ago, conformed 0 bps, exceeded 0 bps Output matches: params: 128000 bps, 8000 limit, 8000 extended limit conformed 9943 packets, 10337248 bytes; action: transmit exceeded 312 packets, 449888 bytes; action: drop last packet: 392ms ago, current burst: 2760 bytes last cleared 00:37:28 ago, conformed 36000 bps, exceeded 1000 bps Any idea why the input limit doesn't work? Thanks in advance Message Posted at: http://www.groupstudy.com/form/read.php?f=7&i=21271&t=21271 -------------------------------------------------- FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]