I think ur missing the command CALLBACK ACCEPT ... its not INITIATE.... also
the computer should be configure to pick the call.... if its windows98 or up
then try configuring computer as DIALUP SERVER (found in dialup networking
icon )

Also try to configure the router first for the nessary things .... dont mess
up by giving many commands it will just confuse u.


-Mamoor

"Sim, CT (Chee Tong)"  wrote in message
news:[EMAIL PROTECTED]...
> Hi.. Farhan and Dear all,
>
> I tried to config for access server to callback PC modem, but it doesn't
> work, could you please check for me what's wrong with the config below.
>
> Sim
>
> access_server#sh run
> Building configuration...
>
> Current configuration:
> !
> version 11.2
> service timestamps debug uptime
> service password-encryption
> no service udp-small-servers
> no service tcp-small-servers
> !
> hostname access_server
> !
> enable secret 5 $XXXXXXXXXXXXXXXX
> !
> username sim callback-dialstring 999999 password XXXXXXXXXXXXXXX
> ip host modem1 2001 50.200.100.11
> ip host modem2 2002 50.200.100.11
> ip host modem3 2003 50.200.100.11
> ip dhcp-server 50.200.100.11
> chat-script script "dialout" ABORT ERROR ABORT BUSY "" "AT" OK "ATDT\T"
> TIMEOUT 30 CONNECT
>  \c
> !
> interface Loopback0
>  ip address 192.198.255.10 255.255.255.255
>  no logging event subif-link-status
> !
> interface Ethernet0
>  ip address 50.200.100.11 255.255.252.0
>  no ip directed-broadcast
>  no logging event subif-link-status
>  load-interval 180
> !
> interface Serial0
>  no ip address
>  no logging event subif-link-status
>  no fair-queue
> !
> interface Async1
>  ip unnumbered Ethernet0
>  encapsulation ppp
>  no logging event subif-link-status
>  async dynamic address
>  async mode interactive
>  peer default ip address dhcp
>  ppp callback initiate
>  ppp authentication pap
> !
> ip classless
> ip route 0.0.0.0 0.0.0.0 50.200.100.1 permanent
> logging trap debugging
> logging facility local3
> logging 50.200.100.22
> snmp-server community public RO
> !
> line con 0
> line 1
>  password 7 XXXXXXXXXX
>  autoselect ppp
>  script callback dialout
>  login local
>  modem InOut
>  modem autoconfigure discovery
>  length 0
>  transport input all
>  speed 115200
>  flowcontrol hardware
> line 2
>  location modem2
>  no exec
>  password 7 XXXXXXXX
>  login
>  modem InOut
>  transport input all
>  speed 115200
>  flowcontrol hardware
> line 3 8
> line aux 0
>  password 7 XXXXXXXXX
>  autoselect ppp
>  login local
>  modem InOut
>  transport input all
>  speed 38400
>  flowcontrol hardware
> line vty 0 4
>  no exec
>  exec-timeout 0 0
>  password 7 XXXXXXXXXX
>  login
> !
> end
>
> access_server#
> access_server#
>
> -----Original Message-----
> From: Farhan Ahmed [mailto:[EMAIL PROTECTED]]
> Sent: Wednesday, August 01, 2001 5:47 PM
> To: 'Sim, CT (Chee Tong)'
> Subject: RE: me again
> Importance: High
>
>
>
> no need
>
> just replace the command
> async mode interactive from dedicated
>
> autoselect ppp
> try
> also
> autoselect during login
> if u have any prob
>
> Best Regards
>
> Have A Good Day!!
>
> *******************************************
> Farhan Ahmed*
>       MCSE+I, MCP Win2k, CCDA, CCNA, CSE
> Network Engineer
> Mideast Data Systems Abudhabi Uae.
>
> *******************************************
>
>
>
> Privileged/Confidential Information may be contained in this message or
> Attachments hereto.  Please advise immediately if you or your employer do
> not consent to Internet email for messages of this kind.  Opinions,
> Conclusions and other information in this message that do not relate to
the
> Official business of this company shall be understood as neither given nor
> Endorsed by it.
>
>
> > -----Original Message-----
> > From: Sim, CT (Chee Tong) [mailto:[EMAIL PROTECTED]]
> > Sent: Wednesday, August 01, 2001 10:49 AM
> > To: 'Farhan Ahmed'
> > Subject: me again
> >
> >
> > Hi.. Farhan, me again
> >
> > May I ask about your script chat script "dialout" ABORT ERROR
> > ABORT BUSY ""
> > "AT" OK "ATDT \T" TIMEOUT 30 CONNECT \c
> > Do you have to specify the the phone no eg 999999 to callback
> > after atdt??
> >
> > What it means by sending you "debug ppp negiotation,
> > authentication"?  Does
> > it refer the debug output on my access server when people dial in.
> >
> > Any configuration need to be done on the WIN98 (mine is
> > WIN98) OS and modem
> > in order to let access server callback.  Do we need to use AT
> > command to
> > configured the PC's modem???
> >
> > Thanks for your help
> > Sim
> > -----Original Message-----
> > From: Sim, CT (Chee Tong)
> > Sent: Wednesday, August 01, 2001 1:46 PM
> > To: 'Farhan Ahmed'
> > Subject: RE: how to configure callback for 2 numbers [7:14121]
> >
> >
> > Farhan,
> >
> > Thanks you your kind help. I think my access-server IOS version not
> > up-to-date is it???  I found my account cannot download IOS
> > software.  May I
> > borrow your account?  Or Please let me know how to get a account to
> > download?
> >
> > Sim
> >
> > access_server#sh ver
> > Cisco Internetwork Operating System Software
> > IOS (tm) 2500 Software (C2500-I-L), Version 11.2(18)P,
> > RELEASE SOFTWARE
> > (fc1)
> > Copyright (c) 1986-1999 by cisco Systems, Inc.
> > Compiled Mon 12-Apr-99 13:29 by ashah
> > Image text-base: 0x030241E0, data-base: 0x00001000
> >
> > ROM: System Bootstrap, Version 11.0(10c)XB1, PLATFORM SPECIFIC RELEASE
> > SOFTWARE (fc1)
> > BOOTFLASH: 3000 Bootstrap Software (IGS-BOOT-R), Version 11.0(10c)XB1,
> > PLATFORM SPECIFIC R
> > ELEASE SOFTWARE (fc1)
> >
> > access_server uptime is 38 weeks, 23 hours, 27 minutes
> >
> >
> > -----Original Message-----
> > From: Farhan Ahmed [mailto:[EMAIL PROTECTED]]
> > Sent: Monday, July 30, 2001 10:34 PM
> > To: [EMAIL PROTECTED]
> > Subject: RE: how to configure callback for 2 numbers [7:14121]
> >
> >
> > try this
> > dont paste
> >
> > username caller1 callback-dialstring  1111 password caller1
> > username caller2 callback-dialstring  2222 password caler2
> >
> > chat script "dialout" ABORT ERROR ABORT BUSY "" "AT" OK "ATDT
> > \T" TIMEOUT 30
> > CONNECT \c
> >
> > interface loopback1
> > ip address 192.168.1.1
> >
> > interface group-async 1
> > encapsulation ppp
> > ip unnumbered interface loopback1
> > ppp authentication pap
> > async mode dedicated
> > peer default ip address pool ip-pool
> > ppp callback accept
> > group range 1 1
> >
> >
> > ip pool ip-pool 192.168.1.2 192.168.1.2
> >
> > line 1
> > modem inout
> > no exec
> > script callback dialout
> > transport input all
> > modem autoconfigure discovery
> > stopbits 1
> > flow control hardware
> >
> >
> >
> > u need to have ios 11.3 2 t or higher
> > 4 win95 callback
> >
> > send me debug ppp negotioation, authentication
> > if u have any problem
> > let me know
> >
> >
> > Best Regards
> >
> > Have A Good Day!!
> >
> > *******************************************
> > Farhan Ahmed*
> >       MCSE+I, MCP Win2k, CCDA, CCNA, CSE
> > Network Engineer
> > Mideast Data Systems Abudhabi Uae.
> >
> > *******************************************
> >
> >
> >
> > Privileged/Confidential Information may be contained in this
> > message or
> > Attachments hereto.  Please advise immediately if you or your
> > employer do
> > not consent to Internet email for messages of this kind.  Opinions,
> > Conclusions and other information in this message that do not
> > relate to the
> > Official business of this company shall be understood as
> > neither given nor
> > Endorsed by it.
> >
> >
> > > -----Original Message-----
> > > From: Sim, CT (Chee Tong) [mailto:[EMAIL PROTECTED]]
> > > Sent: Monday, July 30, 2001 1:56 PM
> > > To: [EMAIL PROTECTED]
> > > Subject: RE: how to configure callback for 2 numbers [7:14121]
> > >
> > >
> > > Yes.. I tried this before, but it come out these errors..
> > > what's wrong??/
> > >
> > >
> > > access_server(config)#username "sim" password "simiscute"
> > > callback-dialstring 999999
> > > % Overly long Password truncated after 25 characters
> > > access_server(config)#username sim password simiscute
> > > callback-dialstring
> > > 999999
> > > % Overly long Password truncated after 25 characters
> > > access_server(config)#username sim password simiscute
> > > [callback-dialstring
> > > 999999]
> > > % Overly long Password truncated after 25 characters
> > >
> > > -----Original Message-----
> > > From: [EMAIL PROTECTED]
> > > [mailto:[EMAIL PROTECTED]]
> > > Sent: Monday, July 30, 2001 5:23 PM
> > > To: [EMAIL PROTECTED]; Sim, CT (Chee Tong)
> > > Subject: RE: how to configure callback for 2 numbers [7:14121]
> > >
> > >
> > >
> > > Specify the call back number in the username configuration:
> > >
> > > username "yourname" password "yourpassword"
> > callback-dialstring 888888
> > > username "yourmate" password "hispassword"
> > callback-dialstring 777777
> > >
> > > CM
> > >
> > >
> > > -----Original Message-----
> > > From: "[EMAIL PROTECTED]"  on behalf of
> > > "Sim, CT (Chee Tong)"
> > > Sent: 30 July 2001 08:04
> > > To: "[EMAIL PROTECTED]"
> > > Subject: how to configure callback for 2 numbers [7:14121]
> > >
> > >
> > >
> > > > ----------
> > > > From: Sim, CT (Chee Tong)[SMTP:[EMAIL PROTECTED]]
> > > > Sent: Monday, July 30, 2001 9:04:53 AM
> > > > To: [EMAIL PROTECTED]
> > > > Subject: how to configure callback for 2 numbers [7:14121]
> > > > Auto forwarded by a Rule
> > > >
> > > Dear all,
> > >
> > > I want to make my access-server to callback my home phone no
> > > 888-888 and my
> > > colleage phone no 777-777, once we use these two number to
> > dial to the
> > > access-server, , after verification, the access server will
> > > cut the line and
> > > call back, no other number can be callbacked.
> > >
> > > Part of my config is as follow, Please tell me what else I
> > > need to configure
> > > in order to make it work.  eg callback-dialstring and etc
> > >
> > > interface Async1
> > >  ip unnumbered Ethernet0
> > >  encapsulation ppp
> > >  no logging event subif-link-status
> > >  async dynamic address
> > >  async mode interactive
> > >  peer default ip address dhcp
> > >  ppp callback accept
> > >  ppp authentication pap
> > > !
> > > line 1
> > >  password 7 00059805050058
> > >  autoselect ppp
> > >  login local
> > >  modem InOut
> > >  length 0
> > >  transport input all
> > >  speed 115200
> > >  flowcontrol hardware
> > >
> > >
> > >
> > >
> > > ==================================================================
> > > De informatie opgenomen in dit bericht kan vertrouwelijk zijn en
> > > is uitsluitend bestemd voor de geadresseerde. Indien u dit bericht
> > > onterecht ontvangt wordt u verzocht de inhoud niet te gebruiken en
> > > de afzender direct te informeren door het bericht te retourneren.
> > > ==================================================================
> > > The information contained in this message may be confidential
> > > and is intended to be exclusively for the addressee. Should you
> > > receive this message unintentionally, please do not use the
> > contents
> > > herein and notify the sender immediately by return e-mail.
> > >
> > >
> > > ==================================================================
> > > ==================================================================
> > > De informatie opgenomen in dit bericht kan vertrouwelijk zijn en
> > > is uitsluitend bestemd voor de geadresseerde. Indien u dit bericht
> > > onterecht ontvangt wordt u verzocht de inhoud niet te gebruiken en
> > > de afzender direct te informeren door het bericht te retourneren.
> > > ==================================================================
> > > The information contained in this message may be confidential
> > > and is intended to be exclusively for the addressee. Should you
> > > receive this message unintentionally, please do not use the
> > contents
> > > herein and notify the sender immediately by return e-mail.
> > >
> > >
> > > ==================================================================
> >
> > [GroupStudy.com removed an attachment of type
> > application/octet-stream which
> > had a name of Farhan Ahmed.vcf]
> > ==================================================================
> > De informatie opgenomen in dit bericht kan vertrouwelijk zijn en
> > is uitsluitend bestemd voor de geadresseerde. Indien u dit bericht
> > onterecht ontvangt wordt u verzocht de inhoud niet te gebruiken en
> > de afzender direct te informeren door het bericht te retourneren.
> > ==================================================================
> > The information contained in this message may be confidential
> > and is intended to be exclusively for the addressee. Should you
> > receive this message unintentionally, please do not use the contents
> > herein and notify the sender immediately by return e-mail.
> >
> >
> > ==================================================================
> >
>
>
> This message was sent with an attachment which Rabobank International does
> not allow because the filetype is not considered to be business related or
> it contains "executable" code which could be destructive if run. Please
note
> the attachment has now been deleted.
>
> The original header content is included below
>
> For more information on Attachment stripping see:
>
> http://i2i.rabobank.com/coc/cces/smtpmail
>
>
>
> The following files were deleted:
> Farhan Ahmed.vcf
>
>
> ==================================================================
>
> ==================================================================
> De informatie opgenomen in dit bericht kan vertrouwelijk zijn en
> is uitsluitend bestemd voor de geadresseerde. Indien u dit bericht
> onterecht ontvangt wordt u verzocht de inhoud niet te gebruiken en
> de afzender direct te informeren door het bericht te retourneren.
> ==================================================================
> The information contained in this message may be confidential
> and is intended to be exclusively for the addressee. Should you
> receive this message unintentionally, please do not use the contents
> herein and notify the sender immediately by return e-mail.
>
>
> ==================================================================




Message Posted at:
http://www.groupstudy.com/form/read.php?f=7&i=14933&t=14767
--------------------------------------------------
FAQ, list archives, and subscription info: http://www.groupstudy.com/list/cisco.html
Report misconduct and Nondisclosure violations to [EMAIL PROTECTED]

Reply via email to